CVE-2016-9159

A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:-:*:*:*:*:*:*:*
OR cpe:2.3:h:siemens:simatic_s7-300_cpu_312:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_pn\/dp:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300_cpu_317-_2_dp:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300_cpu_317-2_pn\/dp:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300_cpu_319-3_pn\/dp:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-400_cpu_firmware:-:*:*:*:*:*:*:*
OR cpe:2.3:h:siemens:simatic_s7-400_cpu_412-1:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-400_cpu_414-2:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\/dp:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-400_cpu_416-2:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\/dp:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-400_cpu_416f-2:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-400_cpu_416f-3_pn\/dp:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-400_cpu_417-4:-:*:*:*:*:*:*:*

History

No history.

Information

Published : 2016-12-17 03:59

Updated : 2023-12-10 12:01


NVD link : CVE-2016-9159

Mitre link : CVE-2016-9159

CVE.ORG link : CVE-2016-9159


JSON object : View

Products Affected

siemens

  • simatic_s7-400_cpu_412-2
  • simatic_s7-400_cpu_417-4
  • simatic_s7-300_cpu_312
  • simatic_s7-300_cpu_319-3_pn\/dp
  • simatic_s7-300_cpu_317-2_pn\/dp
  • simatic_s7-400_cpu_412-2_pn
  • simatic_s7-400_cpu_412-1
  • simatic_s7-400_cpu_414-3_pn\/dp
  • simatic_s7-400_cpu_416f-3_pn\/dp
  • simatic_s7-400_cpu_416-2
  • simatic_s7-300_cpu_317-_2_dp
  • simatic_s7-400_cpu_414-3
  • simatic_s7-400_cpu_firmware
  • simatic_s7-400_cpu_416-3
  • simatic_s7-300_cpu_314
  • simatic_s7-400_cpu_414-2
  • simatic_s7-300_cpu_315-2_pn\/dp
  • simatic_s7-400_cpu_416-3_pn\/dp
  • simatic_s7-400_cpu_416f-2
  • simatic_s7-300_cpu_firmware
  • simatic_s7-300_cpu_315-2_dp
CWE
CWE-200

Exposure of Sensitive Information to an Unauthorized Actor