CVE-2018-13813

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*

Configuration 8 (hide)

OR cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*
cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*

History

No history.

Information

Published : 2018-12-13 16:29

Updated : 2023-12-10 12:44


NVD link : CVE-2018-13813

Mitre link : CVE-2018-13813

CVE.ORG link : CVE-2018-13813


JSON object : View

Products Affected

siemens

  • simatic_hmi_ktp_mobile_panels_ktp900f_firmware
  • simatic_wincc_\(tia_portal\)
  • simatic_hmi_ktp_mobile_panels_ktp900_firmware
  • simatic_wincc_runtime
  • simatic_hmi_ktp_mobile_panels_ktp400f_firmware
  • simatic_hmi_ktp_mobile_panels_ktp700_firmware
  • simatic_hmi_ktp_mobile_panels_ktp700
  • simatic_hmi_op
  • simatic_hmi_mp_firmware
  • simatic_hmi_comfort_outdoor_panels
  • simatic_hmi_tp
  • simatic_hmi_comfort_outdoor_panels_firmware
  • simatic_hmi_ktp_mobile_panels_ktp900
  • simatic_hmi_op_firmware
  • simatic_hmi_tp_firmware
  • simatic_hmi_comfort_panels_firmware
  • simatic_hmi_ktp_mobile_panels_ktp700f_firmware
  • simatic_hmi_ktp_mobile_panels_ktp400f
  • simatic_hmi_ktp_mobile_panels_ktp900f
  • simatic_hmi_ktp_mobile_panels_ktp700f
  • simatic_hmi_comfort_panels
  • simatic_hmi_mp
CWE
CWE-601

URL Redirection to Untrusted Site ('Open Redirect')