CVE-2019-12310

ExaGrid appliances with firmware version v4.8.1.1044.P50 have a /monitor/data/Upgrade/ directory traversal vulnerability, which allows remote attackers to view and retrieve verbose logging information. Files within this directory were observed to contain sensitive run-time information, including Base64 encoded 'support' credentials, leading to administrative access of the device.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:exagrid:backup_appliance_firmware:48.1.1044.p50:*:*:*:*:*:*:*
cpe:2.3:h:exagrid:backup_appliance:-:*:*:*:*:*:*:*

History

No history.

Information

Published : 2019-06-03 19:29

Updated : 2023-12-10 12:59


NVD link : CVE-2019-12310

Mitre link : CVE-2019-12310

CVE.ORG link : CVE-2019-12310


JSON object : View

Products Affected

exagrid

  • backup_appliance
  • backup_appliance_firmware
CWE
CWE-22

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')