CVE-2019-18334

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could be able to enumerate valid user names by sending specifically crafted packets to 8090/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
Link Resource
https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf Mitigation Vendor Advisory
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:siemens:sppa-t3000_application_server:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:sppa-t3000_application_server:r8.2:-:*:*:*:*:*:*
cpe:2.3:a:siemens:sppa-t3000_application_server:r8.2:sp1:*:*:*:*:*:*

History

04 Mar 2022, 20:50

Type Values Removed Values Added
CPE cpe:2.3:a:siemens:sppa-t3000_application_server:r8.2:sp1:*:*:*:*:*:*
cpe:2.3:a:siemens:sppa-t3000_application_server:r8.2:-:*:*:*:*:*:*

24 Feb 2022, 15:15

Type Values Removed Values Added
Summary A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could be able to enumerate valid user names by sending specifically crafted packets to 8090/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could be able to enumerate valid user names by sending specifically crafted packets to 8090/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

22 Feb 2022, 18:15

Type Values Removed Values Added
Summary A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could be able to enumerate valid user names by sending specifically crafted packets to 8090/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could be able to enumerate valid user names by sending specifically crafted packets to 8090/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Information

Published : 2019-12-12 19:15

Updated : 2023-12-10 13:13


NVD link : CVE-2019-18334

Mitre link : CVE-2019-18334

CVE.ORG link : CVE-2019-18334


JSON object : View

Products Affected

siemens

  • sppa-t3000_application_server
CWE
CWE-200

Exposure of Sensitive Information to an Unauthorized Actor