CVE-2019-19295

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) does not enforce logging of security-relevant activities in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker could exploit this vulnerability to perform covert actions that are not visible in the application log.
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:siemens:sinvr_3_central_control_server:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:sinvr_3_video_server:*:*:*:*:*:*:*:*

History

09 Jan 2024, 10:15

Type Values Removed Values Added
Summary (en) A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) does not enforce logging of security-relevant activities in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker could exploit this vulnerability to perform covert actions that are not visible in the application log. (en) A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) does not enforce logging of security-relevant activities in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker could exploit this vulnerability to perform covert actions that are not visible in the application log.

22 Apr 2021, 21:15

Type Values Removed Values Added
Summary A vulnerability has been identified in SiNVR 3 Central Control Server (CCS) (all versions), SiNVR 3 Video Server (all versions). The SiNVR 3 Central Control Server (CCS) does not enforce logging of security-relevant activities in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker could exploit this vulnerability to perform covert actions that are not visible in the application log. A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) does not enforce logging of security-relevant activities in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker could exploit this vulnerability to perform covert actions that are not visible in the application log.

13 Apr 2021, 12:15

Type Values Removed Values Added
CWE NVD-CWE-Other CWE-778
References
  • (CONFIRM) https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf -

Information

Published : 2020-03-10 20:15

Updated : 2024-01-09 10:15


NVD link : CVE-2019-19295

Mitre link : CVE-2019-19295

CVE.ORG link : CVE-2019-19295


JSON object : View

Products Affected

siemens

  • sinvr_3_video_server
  • sinvr_3_central_control_server
CWE
CWE-778

Insufficient Logging

NVD-CWE-Other