CVE-2020-17437

An issue was discovered in uIP 1.0, as used in Contiki 3.0 and other products. When the Urgent flag is set in a TCP packet, and the stack is configured to ignore the urgent data, the stack attempts to use the value of the Urgent pointer bytes to separate the Urgent data from the normal data, by calculating the offset at which the normal data should be present in the global buffer. However, the length of this offset is not checked; therefore, for large values of the Urgent pointer bytes, the data pointer can point to memory that is way beyond the data buffer in uip_process in uip.c.
References
Link Resource
https://cert-portal.siemens.com/productcert/pdf/ssa-541018.pdf Patch Third Party Advisory
https://us-cert.cisa.gov/ics/advisories/icsa-20-343-01 Third Party Advisory US Government Resource
https://www.kb.cert.org/vuls/id/815128 Third Party Advisory US Government Resource
Configurations

Configuration 1 (hide)

AND
cpe:2.3:a:uip_project:uip:*:*:*:*:*:*:*:*
cpe:2.3:o:contiki-os:contiki:*:*:*:*:*:*:*:*

Configuration 2 (hide)

cpe:2.3:a:open-iscsi_project:open-iscsi:*:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:siemens:sentron_3va_com100_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_3va_com100:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:siemens:sentron_3va_com800_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_3va_com800:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:siemens:sentron_3va_dsp800_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_3va_dsp800:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:siemens:sentron_pac2200_clp_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_pac2200_clp:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:siemens:sentron_pac2200_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_pac2200:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:siemens:sentron_pac3200_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_pac3200:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:siemens:sentron_pac3200t_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_pac3200t:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:siemens:sentron_pac3220_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_pac3220:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:siemens:sentron_pac4200_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_pac4200:-:*:*:*:*:*:*:*

History

06 Aug 2022, 03:52

Type Values Removed Values Added
References (CONFIRM) https://cert-portal.siemens.com/productcert/pdf/ssa-541018.pdf - (CONFIRM) https://cert-portal.siemens.com/productcert/pdf/ssa-541018.pdf - Patch, Third Party Advisory
First Time Siemens sentron 3va Com100
Siemens sentron Pac2200 Clp Firmware
Open-iscsi Project open-iscsi
Siemens sentron Pac4200
Siemens sentron Pac2200
Siemens
Open-iscsi Project
Siemens sentron 3va Dsp800 Firmware
Siemens sentron 3va Dsp800
Siemens sentron Pac3200
Siemens sentron Pac3220 Firmware
Siemens sentron 3va Com800 Firmware
Siemens sentron Pac3200 Firmware
Siemens sentron Pac3200t Firmware
Siemens sentron Pac4200 Firmware
Siemens sentron Pac3200t
Siemens sentron 3va Com100 Firmware
Siemens sentron 3va Com800
Siemens sentron Pac2200 Firmware
Siemens sentron Pac2200 Clp
Siemens sentron Pac3220
CPE cpe:2.3:a:uip_project:uip:1.0:*:*:*:*:*:*:*
cpe:2.3:o:contiki-os:contiki:3.0:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_3va_dsp800:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:sentron_pac3200_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_3va_com800:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_pac3200t:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_pac2200_clp:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:sentron_pac4200_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:contiki-os:contiki:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:sentron_pac3220_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:sentron_pac2200_clp_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:sentron_pac2200_firmware:*:*:*:*:*:*:*:*
cpe:2.3:a:uip_project:uip:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:sentron_3va_com800_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_3va_com100:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:sentron_3va_com100_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_pac3200:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_pac3220:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:sentron_3va_dsp800_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_pac4200:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sentron_pac2200:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:sentron_pac3200t_firmware:*:*:*:*:*:*:*:*
cpe:2.3:a:open-iscsi_project:open-iscsi:*:*:*:*:*:*:*:*

09 Mar 2021, 15:15

Type Values Removed Values Added
References
  • (CONFIRM) https://cert-portal.siemens.com/productcert/pdf/ssa-541018.pdf -

Information

Published : 2020-12-11 23:15

Updated : 2023-12-10 13:41


NVD link : CVE-2020-17437

Mitre link : CVE-2020-17437

CVE.ORG link : CVE-2020-17437


JSON object : View

Products Affected

uip_project

  • uip

siemens

  • sentron_pac2200_firmware
  • sentron_pac2200
  • sentron_3va_com800
  • sentron_pac3200t
  • sentron_pac3200
  • sentron_pac4200_firmware
  • sentron_pac3220_firmware
  • sentron_pac3200t_firmware
  • sentron_pac2200_clp_firmware
  • sentron_3va_com100_firmware
  • sentron_3va_dsp800_firmware
  • sentron_pac4200
  • sentron_3va_com100
  • sentron_3va_com800_firmware
  • sentron_pac2200_clp
  • sentron_3va_dsp800
  • sentron_pac3200_firmware
  • sentron_pac3220

contiki-os

  • contiki

open-iscsi_project

  • open-iscsi
CWE
CWE-787