CVE-2020-27736

A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory.
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_readystart_v4:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_source_code:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:siemens:simotics_connect_400_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simotics_connect_400:-:*:*:*:*:*:*:*

History

08 Aug 2023, 10:15

Type Values Removed Values Added
Summary A vulnerability has been identified in Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory. A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory.
References
  • (MISC) https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf -

05 Aug 2022, 17:13

Type Values Removed Values Added
CWE CWE-193
CWE-170
CWE-125

29 Apr 2022, 02:06

Type Values Removed Values Added
CPE cpe:2.3:a:siemens:nucleus_readystart:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:capital_vstar:-:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_4:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_readystart_v4:*:*:*:*:*:*:*:*
First Time Siemens nucleus Readystart V4
Siemens nucleus Readystart V3
CWE CWE-193

11 Jan 2022, 12:15

Type Values Removed Values Added
Summary A vulnerability has been identified in Capital VSTAR (Versions including affected DNS modules), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory. A vulnerability has been identified in Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory.

17 Nov 2021, 22:17

Type Values Removed Values Added
Summary A vulnerability has been identified in Nucleus 4 (All versions < V4.1.0), Nucleus NET (All versions), Nucleus RTOS (versions including affected DNS modules), Nucleus ReadyStart (All versions < V2017.02.3), Nucleus Source Code (versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), VSTAR (versions including affected DNS modules). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory. A vulnerability has been identified in Capital VSTAR (Versions including affected DNS modules), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory.

12 Nov 2021, 19:36

Type Values Removed Values Added
CPE cpe:2.3:a:siemens:vstar:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:nucleus_rtos:-:*:*:*:*:*:*:*
cpe:2.3:a:siemens:capital_vstar:-:*:*:*:*:*:*:*

10 Nov 2021, 01:15

Type Values Removed Values Added
Summary A vulnerability has been identified in Capital VSTAR (Versions including affected DNS modules), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory. A vulnerability has been identified in Nucleus 4 (All versions < V4.1.0), Nucleus NET (All versions), Nucleus RTOS (versions including affected DNS modules), Nucleus ReadyStart (All versions < V2017.02.3), Nucleus Source Code (versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), VSTAR (versions including affected DNS modules). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory.

09 Nov 2021, 12:15

Type Values Removed Values Added
Summary A vulnerability has been identified in Nucleus 4 (All versions < V4.1.0), Nucleus NET (All versions), Nucleus RTOS (versions including affected DNS modules), Nucleus ReadyStart (All versions < V2017.02.3), Nucleus Source Code (versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), VSTAR (versions including affected DNS modules). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory. A vulnerability has been identified in Capital VSTAR (Versions including affected DNS modules), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory.

30 Apr 2021, 14:45

Type Values Removed Values Added
CVSS v2 : unknown
v3 : unknown
v2 : 5.8
v3 : 6.5
References (MISC) https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf - (MISC) https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf - Patch, Vendor Advisory
References (MISC) https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf - (MISC) https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf - Patch, Vendor Advisory
CPE cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_readystart:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simotics_connect_400:-:*:*:*:*:*:*:*
cpe:2.3:a:siemens:vstar:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:nucleus_rtos:-:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_4:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_source_code:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simotics_connect_400_firmware:*:*:*:*:*:*:*:*

22 Apr 2021, 21:16

Type Values Removed Values Added
New CVE

Information

Published : 2021-04-22 21:15

Updated : 2023-12-10 13:55


NVD link : CVE-2020-27736

Mitre link : CVE-2020-27736

CVE.ORG link : CVE-2020-27736


JSON object : View

Products Affected

siemens

  • nucleus_net
  • nucleus_readystart_v4
  • nucleus_readystart_v3
  • nucleus_source_code
  • simotics_connect_400_firmware
  • simotics_connect_400
CWE
CWE-125

Out-of-bounds Read

CWE-170

Improper Null Termination