CVE-2020-5807

An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpy_s() if a local user opens FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) to view the log entry. Observed in FactoryTalk Diagnostics 6.11. All versions of FactoryTalk Diagnostics are affected.
References
Link Resource
https://www.tenable.com/security/research/tra-2020-71 Third Party Advisory
Configurations

Configuration 1 (hide)

cpe:2.3:a:rockwellautomation:factorytalk_diagnostics:*:*:*:*:*:*:*:*

History

30 Dec 2020, 18:44

Type Values Removed Values Added
References (CONFIRM) https://www.tenable.com/security/research/tra-2020-71 - (CONFIRM) https://www.tenable.com/security/research/tra-2020-71 - Third Party Advisory
CPE cpe:2.3:a:rockwellautomation:factorytalk_diagnostics:*:*:*:*:*:*:*:*
CVSS v2 : unknown
v3 : unknown
v2 : 5.0
v3 : 7.5
CWE CWE-755

29 Dec 2020, 16:15

Type Values Removed Values Added
New CVE

Information

Published : 2020-12-29 16:15

Updated : 2023-12-10 13:41


NVD link : CVE-2020-5807

Mitre link : CVE-2020-5807

CVE.ORG link : CVE-2020-5807


JSON object : View

Products Affected

rockwellautomation

  • factorytalk_diagnostics
CWE
CWE-755

Improper Handling of Exceptional Conditions