CVE-2020-6994

A buffer overflow vulnerability was found in some devices of Hirschmann Automation and Control HiOS and HiSecOS. The vulnerability is due to improper parsing of URL arguments. An attacker could exploit this vulnerability by specially crafting HTTP requests to overflow an internal buffer. The following devices using HiOS Version 07.0.02 and lower are affected: RSP, RSPE, RSPS, RSPL, MSP, EES, EES, EESX, GRS, OS, RED. The following devices using HiSecOS Version 03.2.00 and lower are affected: EAGLE20/30.
References
Link Resource
https://www.us-cert.gov/ics/advisories/icsa-20-091-01 Mitigation Third Party Advisory US Government Resource
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:belden:hirschmann_hios:*:*:*:*:*:*:*:*
OR cpe:2.3:h:belden:hirschmann_embedded_ethernet_switch:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_embedded_ethernet_switch_extended:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_greyhound_swtich:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_mice_switch_power:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_octopus:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_prp_redbox:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_rail_switch_power:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_rail_switch_power_enhanced:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_rail_switch_power_lite:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_rail_switch_power_smart:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:belden:hirschmann_hisecos:*:*:*:*:*:*:*:*
OR cpe:2.3:h:belden:hirschmann_eagle20:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_eagle30:-:*:*:*:*:*:*:*

History

17 Jun 2021, 17:22

Type Values Removed Values Added
CPE cpe:2.3:h:hirschmann:embedded_ethernet_switch:-:*:*:*:*:*:*:*
cpe:2.3:h:hirschmann:greyhound_swtich:-:*:*:*:*:*:*:*
cpe:2.3:h:hirschmann:eagle30:-:*:*:*:*:*:*:*
cpe:2.3:h:hirschmann:rail_switch_power_lite:-:*:*:*:*:*:*:*
cpe:2.3:h:hirschmann:octopus:-:*:*:*:*:*:*:*
cpe:2.3:o:hirschmann:hisecos:*:*:*:*:*:*:*:*
cpe:2.3:h:hirschmann:mice_switch_power:-:*:*:*:*:*:*:*
cpe:2.3:h:hirschmann:rail_switch_power_smart:-:*:*:*:*:*:*:*
cpe:2.3:h:hirschmann:embedded_ethernet_switch_extended:-:*:*:*:*:*:*:*
cpe:2.3:o:hirschmann:hios:*:*:*:*:*:*:*:*
cpe:2.3:h:hirschmann:rail_switch_power:-:*:*:*:*:*:*:*
cpe:2.3:h:hirschmann:prp_redbox:-:*:*:*:*:*:*:*
cpe:2.3:h:hirschmann:rail_switch_power_enhanced:-:*:*:*:*:*:*:*
cpe:2.3:h:hirschmann:eagle20:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_greyhound_swtich:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_prp_redbox:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_rail_switch_power_lite:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_rail_switch_power_enhanced:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_mice_switch_power:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_octopus:-:*:*:*:*:*:*:*
cpe:2.3:o:belden:hirschmann_hios:*:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_eagle20:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_rail_switch_power_smart:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_rail_switch_power:-:*:*:*:*:*:*:*
cpe:2.3:o:belden:hirschmann_hisecos:*:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_eagle30:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_embedded_ethernet_switch:-:*:*:*:*:*:*:*
cpe:2.3:h:belden:hirschmann_embedded_ethernet_switch_extended:-:*:*:*:*:*:*:*

Information

Published : 2020-04-03 19:15

Updated : 2023-12-10 13:27


NVD link : CVE-2020-6994

Mitre link : CVE-2020-6994

CVE.ORG link : CVE-2020-6994


JSON object : View

Products Affected

belden

  • hirschmann_eagle30
  • hirschmann_hios
  • hirschmann_rail_switch_power
  • hirschmann_embedded_ethernet_switch
  • hirschmann_rail_switch_power_smart
  • hirschmann_embedded_ethernet_switch_extended
  • hirschmann_eagle20
  • hirschmann_rail_switch_power_enhanced
  • hirschmann_rail_switch_power_lite
  • hirschmann_prp_redbox
  • hirschmann_hisecos
  • hirschmann_greyhound_swtich
  • hirschmann_mice_switch_power
  • hirschmann_octopus
CWE
CWE-120

Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')

CWE-12

ASP.NET Misconfiguration: Missing Custom Error Page