CVE-2020-7489

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller.
References
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:schneider-electric:ecostruxure_machine_expert:*:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:somachine_basic:*:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:schneider-electric:modicon_m100_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:modicon_m100:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:schneider-electric:modicon_m200_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:modicon_m200:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:schneider-electric:modicon_m221_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:modicon_m221:-:*:*:*:*:*:*:*

History

31 Jan 2022, 20:49

Type Values Removed Values Added
CPE cpe:2.3:o:se:modicon_m100_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:se:modicon_m200_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:se:modicon_m221_firmware:*:*:*:*:*:*:*:*
cpe:2.3:a:se:ecostruxure_machine_expert:*:*:*:*:*:*:*:*
cpe:2.3:a:se:somachine_basic:*:*:*:*:*:*:*:*
cpe:2.3:h:se:modicon_m200:-:*:*:*:*:*:*:*
cpe:2.3:h:se:modicon_m100:-:*:*:*:*:*:*:*
cpe:2.3:h:se:modicon_m221:-:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:somachine_basic:*:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_machine_expert:*:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:modicon_m100_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:modicon_m200_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:modicon_m221_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:modicon_m200:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:modicon_m221:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:modicon_m100:-:*:*:*:*:*:*:*
First Time Schneider-electric ecostruxure Machine Expert
Schneider-electric modicon M100 Firmware
Schneider-electric modicon M200 Firmware
Schneider-electric modicon M221 Firmware
Schneider-electric modicon M200
Schneider-electric modicon M221
Schneider-electric modicon M100
Schneider-electric somachine Basic
Schneider-electric

Information

Published : 2020-04-22 19:15

Updated : 2023-12-10 13:27


NVD link : CVE-2020-7489

Mitre link : CVE-2020-7489

CVE.ORG link : CVE-2020-7489


JSON object : View

Products Affected

schneider-electric

  • modicon_m200
  • modicon_m200_firmware
  • somachine_basic
  • modicon_m100_firmware
  • modicon_m100
  • modicon_m221
  • modicon_m221_firmware
  • ecostruxure_machine_expert
CWE
CWE-74

Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')