CVE-2020-7575

A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions < V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users' web sessions.
References
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:siemens:climatix_pol908_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:climatix_pol908:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:siemens:climatix_pol909_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:climatix_pol909:-:*:*:*:*:*:*:*

History

09 Feb 2021, 18:15

Type Values Removed Values Added
Summary A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users' web sessions. A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions < V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users' web sessions.

Information

Published : 2020-04-14 20:15

Updated : 2023-12-10 13:27


NVD link : CVE-2020-7575

Mitre link : CVE-2020-7575

CVE.ORG link : CVE-2020-7575


JSON object : View

Products Affected

siemens

  • climatix_pol909_firmware
  • climatix_pol909
  • climatix_pol908
  • climatix_pol908_firmware
CWE
CWE-79

Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')

CWE-80

Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)