A vulnerability in the CLI of Cisco SD-WAN Software could allow an authenticated, local attacker to overwrite arbitrary files in the underlying file system of an affected system. This vulnerability is due to insufficient validation of the user-supplied input parameters of a specific CLI command. An attacker could exploit this vulnerability by issuing that command with specific parameters. A successful exploit could allow the attacker to overwrite the content in any arbitrary files that reside on the underlying host file system.
References
Link | Resource |
---|---|
https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-sdwan-arbfile-7Qhd9mCn | Vendor Advisory |
Configurations
Configuration 1 (hide)
|
Configuration 2 (hide)
AND |
|
Configuration 3 (hide)
AND |
|
Configuration 4 (hide)
AND |
|
Configuration 5 (hide)
AND |
|
Configuration 6 (hide)
AND |
|
Configuration 7 (hide)
AND |
|
Configuration 8 (hide)
AND |
|
Configuration 9 (hide)
AND |
|
Configuration 10 (hide)
AND |
|
Configuration 11 (hide)
AND |
|
History
16 Oct 2023, 16:35
Type | Values Removed | Values Added |
---|---|---|
First Time |
Cisco catalyst Sd-wan Manager
|
|
CPE | cpe:2.3:a:cisco:catalyst_sd-wan_manager:*:*:*:*:*:*:*:* |
27 Aug 2021, 13:09
Type | Values Removed | Values Added |
---|---|---|
CPE | cpe:2.3:o:cisco:vedge-cloud_firmware:-:*:*:*:*:*:*:* |
cpe:2.3:o:cisco:vedge_cloud_firmware:-:*:*:*:*:*:*:* cpe:2.3:h:cisco:vedge_cloud:-:*:*:*:*:*:*:* |
13 May 2021, 19:51
Type | Values Removed | Values Added |
---|---|---|
CPE | cpe:2.3:a:cisco:sd-wan_vmanage:*:*:*:*:*:*:*:* cpe:2.3:h:cisco:vedge-100b:-:*:*:*:*:*:*:* cpe:2.3:h:cisco:vedge_1000:-:*:*:*:*:*:*:* cpe:2.3:h:cisco:vedge_2000:-:*:*:*:*:*:*:* cpe:2.3:o:cisco:vedge-cloud_firmware:-:*:*:*:*:*:*:* cpe:2.3:o:cisco:vedge_100m_firmware:-:*:*:*:*:*:*:* cpe:2.3:o:cisco:vedge_5000_firmware:-:*:*:*:*:*:*:* cpe:2.3:o:cisco:vsmart_controller_firmware:-:*:*:*:*:*:*:* cpe:2.3:h:cisco:vedge-cloud:-:*:*:*:*:*:*:* cpe:2.3:h:cisco:vedge_5000:-:*:*:*:*:*:*:* cpe:2.3:h:cisco:vedge_100:-:*:*:*:*:*:*:* cpe:2.3:o:cisco:vedge-100b_firmware:-:*:*:*:*:*:*:* cpe:2.3:o:cisco:vedge_1000_firmware:-:*:*:*:*:*:*:* cpe:2.3:h:cisco:vedge_100m:-:*:*:*:*:*:*:* cpe:2.3:o:cisco:vedge_100wm_firmware:-:*:*:*:*:*:*:* cpe:2.3:o:cisco:vedge_2000_firmware:-:*:*:*:*:*:*:* cpe:2.3:a:cisco:sd-wan_vbond_orchestrator:-:*:*:*:*:*:*:* cpe:2.3:h:cisco:vedge_100wm:-:*:*:*:*:*:*:* cpe:2.3:o:cisco:vedge_100_firmware:-:*:*:*:*:*:*:* cpe:2.3:o:cisco:vedge_100b_firmware:-:*:*:*:*:*:*:* cpe:2.3:h:cisco:vsmart_controller:-:*:*:*:*:*:*:* cpe:2.3:h:cisco:vedge_100b:-:*:*:*:*:*:*:* |
|
CVSS |
v2 : v3 : |
v2 : 3.6
v3 : 6.0 |
References | (CISCO) https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-sdwan-arbfile-7Qhd9mCn - Vendor Advisory |
06 May 2021, 13:16
Type | Values Removed | Values Added |
---|---|---|
New CVE |
Information
Published : 2021-05-06 13:15
Updated : 2023-12-10 13:55
NVD link : CVE-2021-1512
Mitre link : CVE-2021-1512
CVE.ORG link : CVE-2021-1512
JSON object : View
Products Affected
cisco
- vedge-100b_firmware
- vedge_1000
- vsmart_controller_firmware
- vedge_cloud
- vedge_1000_firmware
- catalyst_sd-wan_manager
- vedge_2000
- vedge_5000
- sd-wan_vmanage
- vedge_cloud_firmware
- sd-wan_vbond_orchestrator
- vedge_100b
- vedge-100b
- vedge_100wm
- vedge_2000_firmware
- vedge_100m
- vedge_100wm_firmware
- vedge_5000_firmware
- vedge_100_firmware
- vedge_100
- vedge_100b_firmware
- vedge_100m_firmware
- vsmart_controller
CWE
CWE-552