CVE-2021-22706

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:schneider-electric:evlink_city_evc1s22p4_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_city_evc1s22p4:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:schneider-electric:evlink_city_evc1s7p4_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_city_evc1s7p4:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:schneider-electric:evlink_parking_evw2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_parking_evw2:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:schneider-electric:evlink_parking_evf2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_parking_evf2:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:schneider-electric:evlink_parking_ev.2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_parking_ev.2:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:schneider-electric:evlink_smart_wallbox_evb1a_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_smart_wallbox_evb1a:-:*:*:*:*:*:*:*

History

27 Jul 2021, 20:39

Type Values Removed Values Added
CVSS v2 : unknown
v3 : unknown
v2 : 4.3
v3 : 6.1
References (MISC) http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-06 - (MISC) http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-06 - Vendor Advisory
CPE cpe:2.3:h:schneider-electric:evlink_city_evc1s7p4:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_smart_wallbox_evb1a:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:evlink_parking_evf2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_parking_evf2:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:evlink_city_evc1s22p4_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:evlink_city_evc1s7p4_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_city_evc1s22p4:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_parking_evw2:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:evlink_parking_evw2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_parking_ev.2:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:evlink_parking_ev.2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:evlink_smart_wallbox_evb1a_firmware:*:*:*:*:*:*:*:*
CWE CWE-79

21 Jul 2021, 15:21

Type Values Removed Values Added
New CVE

Information

Published : 2021-07-21 15:15

Updated : 2023-12-10 13:55


NVD link : CVE-2021-22706

Mitre link : CVE-2021-22706

CVE.ORG link : CVE-2021-22706


JSON object : View

Products Affected

schneider-electric

  • evlink_parking_evf2
  • evlink_parking_ev.2_firmware
  • evlink_smart_wallbox_evb1a_firmware
  • evlink_parking_evf2_firmware
  • evlink_city_evc1s7p4
  • evlink_parking_ev.2
  • evlink_parking_evw2
  • evlink_smart_wallbox_evb1a
  • evlink_city_evc1s22p4_firmware
  • evlink_city_evc1s7p4_firmware
  • evlink_city_evc1s22p4
  • evlink_parking_evw2_firmware
CWE
CWE-79

Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')