CVE-2021-22722

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Stored Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could cause code injection when importing a CSV file or changing station parameters.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:schneider-electric:evlink_city_evc1s22p4_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_city_evc1s22p4:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:schneider-electric:evlink_city_evc1s7p4_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_city_evc1s7p4:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:schneider-electric:evlink_parking_evw2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_parking_evw2:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:schneider-electric:evlink_parking_evf2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_parking_evf2:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:schneider-electric:evlink_parking_ev.2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_parking_ev.2:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:schneider-electric:evlink_smart_wallbox_evb1a_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_smart_wallbox_evb1a:-:*:*:*:*:*:*:*

History

27 Jul 2021, 20:33

Type Values Removed Values Added
CWE CWE-79
References (MISC) http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-06 - (MISC) http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-06 - Vendor Advisory
CVSS v2 : unknown
v3 : unknown
v2 : 3.5
v3 : 5.4
CPE cpe:2.3:h:schneider-electric:evlink_city_evc1s7p4:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_smart_wallbox_evb1a:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:evlink_parking_evf2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_parking_evf2:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:evlink_city_evc1s22p4_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:evlink_city_evc1s7p4_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_city_evc1s22p4:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_parking_evw2:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:evlink_parking_evw2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:evlink_parking_ev.2:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:evlink_parking_ev.2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:evlink_smart_wallbox_evb1a_firmware:*:*:*:*:*:*:*:*

21 Jul 2021, 15:21

Type Values Removed Values Added
New CVE

Information

Published : 2021-07-21 15:15

Updated : 2023-12-10 13:55


NVD link : CVE-2021-22722

Mitre link : CVE-2021-22722

CVE.ORG link : CVE-2021-22722


JSON object : View

Products Affected

schneider-electric

  • evlink_smart_wallbox_evb1a_firmware
  • evlink_parking_evf2
  • evlink_city_evc1s22p4_firmware
  • evlink_city_evc1s7p4
  • evlink_smart_wallbox_evb1a
  • evlink_city_evc1s22p4
  • evlink_parking_ev.2_firmware
  • evlink_city_evc1s7p4_firmware
  • evlink_parking_ev.2
  • evlink_parking_evw2
  • evlink_parking_evf2_firmware
  • evlink_parking_evw2_firmware
CWE
CWE-79

Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')