CVE-2021-32496

SICK Visionary-S CX up version 5.21.2.29154R are vulnerable to an Inadequate Encryption Strength vulnerability concerning the internal SSH interface solely used by SICK for recovering returned devices. The use of weak ciphers make it easier for an attacker to break the security that protects information transmitted from the client to the SSH server, assuming the attacker has access to the network on which the device is connected. This can increase the risk that encryption will be compromised, leading to the exposure of sensitive user information and man-in-the-middle attacks.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:sick:visionary-s_cx_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:sick:visionary-s_cx:-:*:*:*:*:*:*:*

History

02 Jul 2021, 17:44

Type Values Removed Values Added
CPE cpe:2.3:h:sick:visionary-s_cx:-:*:*:*:*:*:*:*
cpe:2.3:o:sick:visionary-s_cx_firmware:*:*:*:*:*:*:*:*
CWE CWE-326
CVSS v2 : unknown
v3 : unknown
v2 : 3.5
v3 : 5.3
References (MISC) https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories - (MISC) https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories - Vendor Advisory

28 Jun 2021, 12:42

Type Values Removed Values Added
New CVE

Information

Published : 2021-06-28 12:15

Updated : 2023-12-10 13:55


NVD link : CVE-2021-32496

Mitre link : CVE-2021-32496

CVE.ORG link : CVE-2021-32496


JSON object : View

Products Affected

sick

  • visionary-s_cx_firmware
  • visionary-s_cx
CWE
CWE-326

Inadequate Encryption Strength