CVE-2021-37182

A vulnerability has been identified in SCALANCE XM408-4C (All versions < V6.5), SCALANCE XM408-4C (L3 int.) (All versions < V6.5), SCALANCE XM408-8C (All versions < V6.5), SCALANCE XM408-8C (L3 int.) (All versions < V6.5), SCALANCE XM416-4C (All versions < V6.5), SCALANCE XM416-4C (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 1x230V (All versions < V6.5), SCALANCE XR524-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 24V (All versions < V6.5), SCALANCE XR524-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 2x230V (All versions < V6.5), SCALANCE XR524-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 1x230V (All versions < V6.5), SCALANCE XR526-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 24V (All versions < V6.5), SCALANCE XR526-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 2x230V (All versions < V6.5), SCALANCE XR526-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR528-6M (All versions < V6.5), SCALANCE XR528-6M (2HR2) (All versions < V6.5), SCALANCE XR528-6M (2HR2, L3 int.) (All versions < V6.5), SCALANCE XR528-6M (L3 int.) (All versions < V6.5), SCALANCE XR552-12M (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2, L3 int.) (All versions < V6.5). The OSPF protocol implementation in affected devices fails to verify the checksum and length fields in the OSPF LS Update messages. An unauthenticated remote attacker could exploit this vulnerability to cause interruptions in the network by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device.
References
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:siemens:scalance_xm408-4c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:siemens:scalance_xm408-4c_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xm408-4c_l3:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:siemens:scalance_xm408-8c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:siemens:scalance_xm408-8c_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xm408-8c_l3:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:siemens:scalance_xm416-4c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:siemens:scalance_xm416-4c_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xm416-4c_l3:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:1x230v:*
cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:1x230v:*

Configuration 9 (hide)

AND
cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:24v:*
cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:24v:*

Configuration 10 (hide)

AND
cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:2x230v:*
cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:2x230v:*

Configuration 11 (hide)

AND
cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:*:*

Configuration 12 (hide)

AND
cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:1x230v:*
cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:1x230v:*

Configuration 13 (hide)

AND
cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:24v:*
cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:24v:*

Configuration 14 (hide)

AND
cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:2x230v:*
cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:2x230v:*

Configuration 15 (hide)

AND
cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*

Configuration 16 (hide)

AND
cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:1x230v:*
cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:1x230v:*

Configuration 17 (hide)

AND
cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:24v:*
cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:24v:*

Configuration 18 (hide)

AND
cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:2x230v:*
cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:2x230v:*

Configuration 19 (hide)

AND
cpe:2.3:o:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:*:*

Configuration 20 (hide)

AND
cpe:2.3:o:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:1x230v:*
cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:1x230v:*

Configuration 21 (hide)

AND
cpe:2.3:o:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:24v:*
cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:24v:*

Configuration 22 (hide)

AND
cpe:2.3:o:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:2x230v:*
cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:2x230v:*

Configuration 23 (hide)

AND
cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*

Configuration 24 (hide)

AND
cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr528-6m_2hr2:-:*:*:*:*:*:*:*

Configuration 25 (hide)

AND
cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr528-6m_2hr2_l3:-:*:*:*:*:*:*:*

Configuration 26 (hide)

AND
cpe:2.3:o:siemens:scalance_xr528-6m_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr528-6m_l3:-:*:*:*:*:*:*:*

Configuration 27 (hide)

AND
cpe:2.3:o:siemens:scalance_xr552-12m_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr552-12m:-:*:*:*:*:*:*:*

Configuration 28 (hide)

AND
cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr552-12m_2hr2:-:*:*:*:*:*:*:*

Configuration 29 (hide)

AND
cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr552-12m_2hr2_l3:-:*:*:*:*:*:*:*

History

27 Jun 2022, 17:40

Type Values Removed Values Added
References (MISC) https://cert-portal.siemens.com/productcert/pdf/ssa-145224.pdf - (MISC) https://cert-portal.siemens.com/productcert/pdf/ssa-145224.pdf - Patch, Vendor Advisory
CWE CWE-354
First Time Siemens scalance Xr526-8c
Siemens scalance Xr528-6m 2hr2 L3 Firmware
Siemens scalance Xr528-6m 2hr2 L3
Siemens scalance Xr528-6m L3
Siemens scalance Xr526-8c L3
Siemens scalance Xr526-8c L3 Firmware
Siemens scalance Xr526-8c Firmware
Siemens scalance Xr524-8c L3
Siemens scalance Xm416-4c L3 Firmware
Siemens scalance Xm408-4c L3 Firmware
Siemens scalance Xm408-4c L3
Siemens scalance Xr528-6m L3 Firmware
Siemens scalance Xr552-12m 2hr2 L3
Siemens scalance Xr524-8c
Siemens scalance Xm408-4c
Siemens scalance Xm408-8c
Siemens scalance Xr524-8c L3 Firmware
Siemens scalance Xr552-12m 2hr2 Firmware
Siemens scalance Xr528-6m 2hr2 Firmware
Siemens scalance Xm416-4c Firmware
Siemens scalance Xm408-4c Firmware
Siemens
Siemens scalance Xm416-4c L3
Siemens scalance Xm408-8c L3 Firmware
Siemens scalance Xr552-12m
Siemens scalance Xr528-6m 2hr2
Siemens scalance Xr528-6m Firmware
Siemens scalance Xr528-6m
Siemens scalance Xr552-12m 2hr2 L3 Firmware
Siemens scalance Xm416-4c
Siemens scalance Xm408-8c L3
Siemens scalance Xr552-12m Firmware
Siemens scalance Xr524-8c Firmware
Siemens scalance Xm408-8c Firmware
Siemens scalance Xr552-12m 2hr2
CVSS v2 : unknown
v3 : unknown
v2 : 4.3
v3 : 7.5
CPE cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:1x230v:*
cpe:2.3:h:siemens:scalance_xr552-12m_2hr2_l3:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xm408-8c_l3:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:2x230v:*
cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:1x230v:*
cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:24v:*
cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:2x230v:*
cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:2x230v:*
cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr528-6m_2hr2:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_xr528-6m_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:1x230v:*
cpe:2.3:o:siemens:scalance_xm408-4c_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:2x230v:*
cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:2x230v:*
cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_xm408-4c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_xm416-4c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:2x230v:*
cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:24v:*
cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:2x230v:*
cpe:2.3:o:siemens:scalance_xr552-12m_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xm416-4c_l3:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr552-12m:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_xm408-8c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr552-12m_2hr2:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr528-6m_2hr2_l3:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:24v:*
cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_xm416-4c_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:2x230v:*
cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:1x230v:*
cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:1x230v:*
cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:24v:*
cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:24v:*
cpe:2.3:h:siemens:scalance_xr528-6m_l3:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:24v:*
cpe:2.3:h:siemens:scalance_xm408-4c_l3:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_xm408-8c_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:1x230v:*
cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:1x230v:*
cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:24v:*
cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:1x230v:*
cpe:2.3:o:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:24v:*

14 Jun 2022, 10:15

Type Values Removed Values Added
New CVE

Information

Published : 2022-06-14 10:15

Updated : 2023-12-10 14:22


NVD link : CVE-2021-37182

Mitre link : CVE-2021-37182

CVE.ORG link : CVE-2021-37182


JSON object : View

Products Affected

siemens

  • scalance_xr552-12m_2hr2_l3_firmware
  • scalance_xm408-8c_firmware
  • scalance_xm408-8c
  • scalance_xm416-4c_l3
  • scalance_xr552-12m
  • scalance_xr528-6m_l3_firmware
  • scalance_xr528-6m_2hr2_firmware
  • scalance_xr526-8c
  • scalance_xr528-6m_2hr2_l3
  • scalance_xm408-4c_l3
  • scalance_xr552-12m_2hr2_firmware
  • scalance_xm408-4c_l3_firmware
  • scalance_xr552-12m_2hr2_l3
  • scalance_xm408-8c_l3
  • scalance_xr524-8c
  • scalance_xm408-4c_firmware
  • scalance_xm416-4c_l3_firmware
  • scalance_xr526-8c_firmware
  • scalance_xm416-4c_firmware
  • scalance_xr526-8c_l3_firmware
  • scalance_xr524-8c_l3
  • scalance_xm408-8c_l3_firmware
  • scalance_xr552-12m_firmware
  • scalance_xr524-8c_firmware
  • scalance_xr528-6m_l3
  • scalance_xr528-6m_2hr2_l3_firmware
  • scalance_xr528-6m_firmware
  • scalance_xm416-4c
  • scalance_xr526-8c_l3
  • scalance_xr524-8c_l3_firmware
  • scalance_xr528-6m_2hr2
  • scalance_xm408-4c
  • scalance_xr528-6m
  • scalance_xr552-12m_2hr2
CWE
CWE-354

Improper Validation of Integrity Check Value