CVE-2021-42059

An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver.
Configurations

Configuration 1 (hide)

cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*

Configuration 2 (hide)

cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*

Configuration 3 (hide)

cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*

Configuration 4 (hide)

cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*

Configuration 5 (hide)

cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc127e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc227g_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc277g_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc327g_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:*

Configuration 12 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc377g_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:*

Configuration 13 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*

Configuration 14 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*

Configuration 15 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc627e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*

Configuration 16 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc647e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*

Configuration 17 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc677e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:*

Configuration 18 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc847e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*

Configuration 19 (hide)

AND
cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*

History

18 Apr 2022, 18:02

Type Values Removed Values Added
First Time Siemens simatic Ipc627e Firmware
Siemens
Siemens simatic Ipc677e
Siemens simatic Ipc377g Firmware
Siemens simatic Ipc847e
Siemens simatic Ipc127e Firmware
Siemens simatic Ipc277g
Siemens simatic Ipc277g Firmware
Siemens simatic Ipc327g Firmware
Siemens simatic Ipc477e Firmware
Siemens simatic Ipc427e Firmware
Siemens simatic Ipc847e Firmware
Siemens simatic Ipc377g
Siemens simatic Itp1000
Siemens simatic Field Pg M6 Firmware
Siemens simatic Ipc227g Firmware
Siemens simatic Ipc127e
Siemens simatic Ipc477e
Siemens simatic Field Pg M5 Firmware
Siemens simatic Ipc647e
Siemens simatic Field Pg M6
Siemens simatic Ipc427e
Siemens simatic Field Pg M5
Siemens simatic Ipc677e Firmware
Siemens simatic Ipc647e Firmware
Siemens simatic Ipc327g
Siemens simatic Ipc627e
Siemens simatic Ipc227g
Siemens simatic Itp1000 Firmware
CPE cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_ipc127e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_ipc627e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_ipc847e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_ipc227g_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_ipc277g_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_ipc677e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_ipc327g_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_ipc377g_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_ipc647e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*
References (CONFIRM) https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf - (CONFIRM) https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf - Third Party Advisory
References (MISC) https://www.insyde.com/security-pledge/SA-2022006 - (MISC) https://www.insyde.com/security-pledge/SA-2022006 - Vendor Advisory
References (CONFIRM) https://security.netapp.com/advisory/ntap-20220216-0008/ - (CONFIRM) https://security.netapp.com/advisory/ntap-20220216-0008/ - Third Party Advisory

24 Feb 2022, 15:15

Type Values Removed Values Added
References
  • (CONFIRM) https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf -

17 Feb 2022, 01:15

Type Values Removed Values Added
References
  • (CONFIRM) https://security.netapp.com/advisory/ntap-20220216-0008/ -

09 Feb 2022, 03:15

Type Values Removed Values Added
Summary Stack overflow vulnerability that allows a local root user to access UEFI DXE driver and execute arbitrary code. An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver.
References
  • (MISC) https://www.insyde.com/security-pledge/SA-2022006 -

05 Feb 2022, 04:52

Type Values Removed Values Added
CPE cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*
First Time Insyde
Insyde insydeh2o
CVSS v2 : unknown
v3 : unknown
v2 : 7.2
v3 : 6.7
References (MISC) https://www.insyde.com/security-pledge - (MISC) https://www.insyde.com/security-pledge - Vendor Advisory
CWE CWE-787

03 Feb 2022, 02:15

Type Values Removed Values Added
New CVE

Information

Published : 2022-02-03 02:15

Updated : 2023-12-10 14:09


NVD link : CVE-2021-42059

Mitre link : CVE-2021-42059

CVE.ORG link : CVE-2021-42059


JSON object : View

Products Affected

siemens

  • simatic_ipc647e
  • simatic_ipc627e_firmware
  • simatic_itp1000
  • simatic_field_pg_m6
  • simatic_field_pg_m5
  • simatic_ipc377g_firmware
  • simatic_ipc427e
  • simatic_itp1000_firmware
  • simatic_ipc677e
  • simatic_ipc477e_firmware
  • simatic_ipc847e
  • simatic_field_pg_m5_firmware
  • simatic_ipc377g
  • simatic_ipc277g_firmware
  • simatic_field_pg_m6_firmware
  • simatic_ipc677e_firmware
  • simatic_ipc847e_firmware
  • simatic_ipc227g
  • simatic_ipc627e
  • simatic_ipc227g_firmware
  • simatic_ipc427e_firmware
  • simatic_ipc327g_firmware
  • simatic_ipc127e
  • simatic_ipc277g
  • simatic_ipc127e_firmware
  • simatic_ipc647e_firmware
  • simatic_ipc327g
  • simatic_ipc477e

insyde

  • insydeh2o
CWE
CWE-787

Out-of-bounds Write