CVE-2022-22808

A CWE-352: Cross-Site Request Forgery (CSRF) exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)
References
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:schneider-electric:hmibscea53d1edb_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:hmibscea53d1edb:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:schneider-electric:hmibscea53d1eds_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:hmibscea53d1eds:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:schneider-electric:hmibscea53d1edm_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:hmibscea53d1edm:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:schneider-electric:hmibscea53d1edl_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:hmibscea53d1edl:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:schneider-electric:hmibscea53d1ess_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:hmibscea53d1ess:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:schneider-electric:hmibscea53d1esm_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:hmibscea53d1esm:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:schneider-electric:hmibscea53d1eml_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:hmibscea53d1eml:-:*:*:*:*:*:*:*

History

10 Nov 2022, 22:15

Type Values Removed Values Added
Summary A CWE-942: Permissive Cross-domain Policy with Untrusted Domains vulnerability exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13) A CWE-352: Cross-Site Request Forgery (CSRF) exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)

16 Feb 2022, 17:04

Type Values Removed Values Added
References (MISC) https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-02 - (MISC) https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-02 - Patch, Vendor Advisory
CPE cpe:2.3:o:schneider-electric:hmibscea53d1eds_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:hmibscea53d1edl_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:hmibscea53d1eml_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:hmibscea53d1edm_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:hmibscea53d1edb:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:hmibscea53d1eds:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:hmibscea53d1esm_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:hmibscea53d1esm:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:hmibscea53d1eml:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:hmibscea53d1ess_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:hmibscea53d1ess:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:hmibscea53d1edl:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:hmibscea53d1edb_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:hmibscea53d1edm:-:*:*:*:*:*:*:*
CVSS v2 : unknown
v3 : unknown
v2 : 6.8
v3 : 8.8
First Time Schneider-electric hmibscea53d1eml
Schneider-electric hmibscea53d1eds Firmware
Schneider-electric hmibscea53d1edb
Schneider-electric hmibscea53d1ess Firmware
Schneider-electric hmibscea53d1edm
Schneider-electric hmibscea53d1edl Firmware
Schneider-electric hmibscea53d1edb Firmware
Schneider-electric hmibscea53d1eml Firmware
Schneider-electric hmibscea53d1edl
Schneider-electric hmibscea53d1ess
Schneider-electric hmibscea53d1esm Firmware
Schneider-electric
Schneider-electric hmibscea53d1esm
Schneider-electric hmibscea53d1edm Firmware
Schneider-electric hmibscea53d1eds
CWE CWE-942 CWE-352

09 Feb 2022, 23:15

Type Values Removed Values Added
New CVE

Information

Published : 2022-02-09 23:15

Updated : 2023-12-10 14:22


NVD link : CVE-2022-22808

Mitre link : CVE-2022-22808

CVE.ORG link : CVE-2022-22808


JSON object : View

Products Affected

schneider-electric

  • hmibscea53d1eds_firmware
  • hmibscea53d1ess
  • hmibscea53d1eds
  • hmibscea53d1esm
  • hmibscea53d1eml
  • hmibscea53d1edm
  • hmibscea53d1edb_firmware
  • hmibscea53d1esm_firmware
  • hmibscea53d1eml_firmware
  • hmibscea53d1edl_firmware
  • hmibscea53d1edb
  • hmibscea53d1ess_firmware
  • hmibscea53d1edm_firmware
  • hmibscea53d1edl
CWE
CWE-352

Cross-Site Request Forgery (CSRF)