CVE-2022-24286

Acer QuickAccess 2.01.300x before 2.01.3030 and 3.00.30xx before 3.00.3038 contains a local privilege escalation vulnerability. The user process communicates with a service of system authority through a named pipe. In this case, the Named Pipe is also given Read and Write rights to the general user. In addition, the service program does not verify the user when communicating. A thread may exist with a specific command. When the path of the program to be executed is sent, there is a local privilege escalation in which the service program executes the path with system privileges.
References
Link Resource
https://community.acer.com/en/kb/articles/14762 Mitigation Vendor Advisory
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:acer:quickaccess:*:*:*:*:*:*:*:*
cpe:2.3:a:acer:quickaccess:*:*:*:*:*:*:*:*

History

16 Mar 2022, 17:44

Type Values Removed Values Added
CWE CWE-287
CVSS v2 : unknown
v3 : unknown
v2 : 7.2
v3 : 7.8
References (MISC) https://community.acer.com/en/kb/articles/14762 - (MISC) https://community.acer.com/en/kb/articles/14762 - Mitigation, Vendor Advisory
First Time Acer quickaccess
Acer
CPE cpe:2.3:a:acer:quickaccess:*:*:*:*:*:*:*:*

10 Mar 2022, 17:53

Type Values Removed Values Added
New CVE

Information

Published : 2022-03-10 17:46

Updated : 2023-12-10 14:22


NVD link : CVE-2022-24286

Mitre link : CVE-2022-24286

CVE.ORG link : CVE-2022-24286


JSON object : View

Products Affected

acer

  • quickaccess
CWE
CWE-287

Improper Authentication