CVE-2022-44731

A vulnerability has been identified in SIMATIC WinCC OA V3.15 (All versions < V3.15 P038), SIMATIC WinCC OA V3.16 (All versions < V3.16 P035), SIMATIC WinCC OA V3.17 (All versions < V3.17 P024), SIMATIC WinCC OA V3.18 (All versions < V3.18 P014). The affected component allows to inject custom arguments to the Ultralight Client backend application under certain circumstances. This could allow an authenticated remote attacker to inject arbitrary parameters when starting the client via the web interface (e.g., open attacker chosen panels with the attacker's credentials or start a Ctrl script).
References
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:siemens:simatic_wincc_oa:3.15:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_oa:3.16:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_oa:3.17:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_oa:3.18:-:*:*:*:*:*:*

History

07 Nov 2023, 03:54

Type Values Removed Values Added
Summary A vulnerability has been identified in SIMATIC WinCC OA V3.15 (All versions < V3.15 P038), SIMATIC WinCC OA V3.16 (All versions < V3.16 P035), SIMATIC WinCC OA V3.17 (All versions < V3.17 P024), SIMATIC WinCC OA V3.18 (All versions < V3.18 P014). The affected component allows to inject custom arguments to the Ultralight Client backend application under certain circumstances. This could allow an authenticated remote attacker to inject arbitrary parameters when starting the client via the web interface (e.g., open attacker chosen panels with the attacker's credentials or start a Ctrl script). A vulnerability has been identified in SIMATIC WinCC OA V3.15 (All versions < V3.15 P038), SIMATIC WinCC OA V3.16 (All versions < V3.16 P035), SIMATIC WinCC OA V3.17 (All versions < V3.17 P024), SIMATIC WinCC OA V3.18 (All versions < V3.18 P014). The affected component allows to inject custom arguments to the Ultralight Client backend application under certain circumstances. This could allow an authenticated remote attacker to inject arbitrary parameters when starting the client via the web interface (e.g., open attacker chosen panels with the attacker's credentials or start a Ctrl script).

10 Jan 2023, 12:15

Type Values Removed Values Added
Summary A vulnerability has been identified in SIMATIC WinCC OA V3.15 (All versions), SIMATIC WinCC OA V3.16 (All versions < V3.16 P035), SIMATIC WinCC OA V3.17 (All versions < V3.17 P024), SIMATIC WinCC OA V3.18 (All versions < V3.18 P014). The affected component allows to inject custom arguments to the Ultralight Client backend application under certain circumstances. This could allow an authenticated remote attacker to inject arbitrary parameters when starting the client via the web interface (e.g., open attacker chosen panels with the attacker's credentials or start a Ctrl script). A vulnerability has been identified in SIMATIC WinCC OA V3.15 (All versions < V3.15 P038), SIMATIC WinCC OA V3.16 (All versions < V3.16 P035), SIMATIC WinCC OA V3.17 (All versions < V3.17 P024), SIMATIC WinCC OA V3.18 (All versions < V3.18 P014). The affected component allows to inject custom arguments to the Ultralight Client backend application under certain circumstances. This could allow an authenticated remote attacker to inject arbitrary parameters when starting the client via the web interface (e.g., open attacker chosen panels with the attacker's credentials or start a Ctrl script).

15 Dec 2022, 20:16

Type Values Removed Values Added
CVSS v2 : unknown
v3 : unknown
v2 : unknown
v3 : 5.4
References (CONFIRM) https://cert-portal.siemens.com/productcert/pdf/ssa-547714.pdf - (CONFIRM) https://cert-portal.siemens.com/productcert/pdf/ssa-547714.pdf - Patch, Vendor Advisory
First Time Siemens simatic Wincc Oa
Siemens
CWE CWE-88
CPE cpe:2.3:a:siemens:simatic_wincc_oa:3.16:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_oa:3.17:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_oa:3.15:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_oa:3.18:-:*:*:*:*:*:*

13 Dec 2022, 17:15

Type Values Removed Values Added
New CVE

Information

Published : 2022-12-13 16:15

Updated : 2023-12-10 14:48


NVD link : CVE-2022-44731

Mitre link : CVE-2022-44731

CVE.ORG link : CVE-2022-44731


JSON object : View

Products Affected

siemens

  • simatic_wincc_oa
CWE
CWE-88

Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')