CVE-2022-45139

A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality.
References
Link Resource
https://cert.vde.com/en/advisories/VDE-2022-060/ Third Party Advisory
Configurations

Configuration 1 (hide)

AND
OR cpe:2.3:o:wago:751-9301_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:wago:751-9301_firmware:22:-:*:*:*:*:*:*
cpe:2.3:o:wago:751-9301_firmware:23:*:*:*:*:*:*:*
cpe:2.3:h:wago:751-9301:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
OR cpe:2.3:o:wago:752-8303\/8000-002_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:wago:752-8303\/8000-002_firmware:22:-:*:*:*:*:*:*
cpe:2.3:o:wago:752-8303\/8000-002_firmware:23:*:*:*:*:*:*:*
cpe:2.3:h:wago:752-8303\/8000-002:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
OR cpe:2.3:o:wago:pfc100_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:wago:pfc100_firmware:22:-:*:*:*:*:*:*
cpe:2.3:o:wago:pfc100_firmware:23:*:*:*:*:*:*:*
cpe:2.3:h:wago:pfc100:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
OR cpe:2.3:o:wago:pfc200_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:wago:pfc200_firmware:22:-:*:*:*:*:*:*
cpe:2.3:o:wago:pfc200_firmware:23:*:*:*:*:*:*:*
cpe:2.3:h:wago:pfc200:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
OR cpe:2.3:o:wago:touch_panel_600_advanced_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:wago:touch_panel_600_advanced_firmware:22:-:*:*:*:*:*:*
cpe:2.3:o:wago:touch_panel_600_advanced_firmware:23:*:*:*:*:*:*:*
cpe:2.3:h:wago:touch_panel_600_advanced:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
OR cpe:2.3:o:wago:touch_panel_600_marine_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:wago:touch_panel_600_marine_firmware:22:-:*:*:*:*:*:*
cpe:2.3:o:wago:touch_panel_600_marine_firmware:23:*:*:*:*:*:*:*
cpe:2.3:h:wago:touch_panel_600_marine:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
OR cpe:2.3:o:wago:touch_panel_600_standard_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:wago:touch_panel_600_standard_firmware:22:-:*:*:*:*:*:*
cpe:2.3:o:wago:touch_panel_600_standard_firmware:23:*:*:*:*:*:*:*
cpe:2.3:h:wago:touch_panel_600_standard:-:*:*:*:*:*:*:*

History

07 Mar 2023, 22:54

Type Values Removed Values Added
First Time Wago pfc100 Firmware
Wago 751-9301
Wago touch Panel 600 Standard Firmware
Wago touch Panel 600 Marine Firmware
Wago 751-9301 Firmware
Wago 752-8303\/8000-002 Firmware
Wago touch Panel 600 Advanced
Wago pfc200 Firmware
Wago touch Panel 600 Standard
Wago pfc100
Wago 752-8303\/8000-002
Wago touch Panel 600 Advanced Firmware
Wago pfc200
Wago touch Panel 600 Marine
Wago
References (MISC) https://cert.vde.com/en/advisories/VDE-2022-060/ - (MISC) https://cert.vde.com/en/advisories/VDE-2022-060/ - Third Party Advisory
CPE cpe:2.3:o:wago:touch_panel_600_advanced_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:wago:touch_panel_600_marine:-:*:*:*:*:*:*:*
cpe:2.3:h:wago:752-8303\/8000-002:-:*:*:*:*:*:*:*
cpe:2.3:o:wago:751-9301_firmware:23:*:*:*:*:*:*:*
cpe:2.3:o:wago:touch_panel_600_marine_firmware:22:-:*:*:*:*:*:*
cpe:2.3:o:wago:pfc100_firmware:22:-:*:*:*:*:*:*
cpe:2.3:o:wago:touch_panel_600_advanced_firmware:23:*:*:*:*:*:*:*
cpe:2.3:o:wago:752-8303\/8000-002_firmware:23:*:*:*:*:*:*:*
cpe:2.3:h:wago:pfc200:-:*:*:*:*:*:*:*
cpe:2.3:o:wago:touch_panel_600_marine_firmware:23:*:*:*:*:*:*:*
cpe:2.3:o:wago:pfc100_firmware:23:*:*:*:*:*:*:*
cpe:2.3:h:wago:751-9301:-:*:*:*:*:*:*:*
cpe:2.3:o:wago:pfc200_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:wago:touch_panel_600_advanced:-:*:*:*:*:*:*:*
cpe:2.3:o:wago:pfc200_firmware:22:-:*:*:*:*:*:*
cpe:2.3:o:wago:751-9301_firmware:22:-:*:*:*:*:*:*
cpe:2.3:o:wago:touch_panel_600_standard_firmware:22:-:*:*:*:*:*:*
cpe:2.3:o:wago:752-8303\/8000-002_firmware:22:-:*:*:*:*:*:*
cpe:2.3:o:wago:touch_panel_600_advanced_firmware:22:-:*:*:*:*:*:*
cpe:2.3:o:wago:752-8303\/8000-002_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:wago:751-9301_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:wago:touch_panel_600_marine_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:wago:touch_panel_600_standard:-:*:*:*:*:*:*:*
cpe:2.3:h:wago:pfc100:-:*:*:*:*:*:*:*
cpe:2.3:o:wago:pfc100_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:wago:touch_panel_600_standard_firmware:23:*:*:*:*:*:*:*
cpe:2.3:o:wago:pfc200_firmware:23:*:*:*:*:*:*:*
cpe:2.3:o:wago:touch_panel_600_standard_firmware:*:*:*:*:*:*:*:*

27 Feb 2023, 15:20

Type Values Removed Values Added
New CVE

Information

Published : 2023-02-27 15:15

Updated : 2023-12-10 14:48


NVD link : CVE-2022-45139

Mitre link : CVE-2022-45139

CVE.ORG link : CVE-2022-45139


JSON object : View

Products Affected

wago

  • touch_panel_600_standard
  • touch_panel_600_standard_firmware
  • 751-9301_firmware
  • pfc200_firmware
  • touch_panel_600_marine_firmware
  • touch_panel_600_advanced
  • 752-8303\/8000-002
  • pfc100_firmware
  • pfc100
  • touch_panel_600_advanced_firmware
  • pfc200
  • touch_panel_600_marine
  • 752-8303\/8000-002_firmware
  • 751-9301
CWE
CWE-346

Origin Validation Error