CVE-2022-46670

Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution.  The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:rockwellautomation:micrologix_1400_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:micrologix_1400:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:rockwellautomation:micrologix_1100_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:micrologix_1100:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:rockwellautomation:micrologix_1400-b_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:micrologix_1400-b:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:rockwellautomation:micrologix_1400-c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:micrologix_1400-c:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:rockwellautomation:micrologix_1400-a_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:micrologix_1400-a:-:*:*:*:*:*:*:*

History

07 Nov 2023, 03:55

Type Values Removed Values Added
Summary Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website. Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution.  The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website.

22 Dec 2022, 18:28

Type Values Removed Values Added
CVSS v2 : unknown
v3 : unknown
v2 : unknown
v3 : 6.1
CPE cpe:2.3:h:rockwellautomation:micrologix_1100:-:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:micrologix_1400-a:-:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:micrologix_1400:-:*:*:*:*:*:*:*
cpe:2.3:o:rockwellautomation:micrologix_1400-c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:rockwellautomation:micrologix_1400_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:micrologix_1400-c:-:*:*:*:*:*:*:*
cpe:2.3:o:rockwellautomation:micrologix_1400-a_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:rockwellautomation:micrologix_1400-b_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:rockwellautomation:micrologix_1100_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:micrologix_1400-b:-:*:*:*:*:*:*:*
References (MISC) https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679 - (MISC) https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679 - Vendor Advisory
CWE CWE-79
First Time Rockwellautomation micrologix 1100 Firmware
Rockwellautomation micrologix 1400 Firmware
Rockwellautomation micrologix 1400-c
Rockwellautomation micrologix 1400-b
Rockwellautomation micrologix 1400-a Firmware
Rockwellautomation micrologix 1400
Rockwellautomation
Rockwellautomation micrologix 1400-b Firmware
Rockwellautomation micrologix 1400-c Firmware
Rockwellautomation micrologix 1100
Rockwellautomation micrologix 1400-a

16 Dec 2022, 22:03

Type Values Removed Values Added
New CVE

Information

Published : 2022-12-16 21:15

Updated : 2023-12-10 14:48


NVD link : CVE-2022-46670

Mitre link : CVE-2022-46670

CVE.ORG link : CVE-2022-46670


JSON object : View

Products Affected

rockwellautomation

  • micrologix_1400-c
  • micrologix_1400-a_firmware
  • micrologix_1400-b
  • micrologix_1400-c_firmware
  • micrologix_1100_firmware
  • micrologix_1400-a
  • micrologix_1400_firmware
  • micrologix_1100
  • micrologix_1400-b_firmware
  • micrologix_1400
CWE
CWE-79

Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')