CVE-2023-25719

ConnectWise Control before 22.9.10032 (formerly known as ScreenConnect) fails to validate user-supplied parameters such as the Bin/ConnectWiseControl.Client.exe h parameter. This results in reflected data and injection of malicious code into a downloaded executable. The executable can be used to execute malicious queries or as a denial-of-service vector. NOTE: this CVE Record is only about the parameters, such as the h parameter (this CVE Record is not about the separate issue of signed executable files that are supposed to have unique configurations across customers' installations).
Configurations

Configuration 1 (hide)

cpe:2.3:a:connectwise:control:*:*:*:*:*:*:*:*

History

05 Mar 2023, 20:15

Type Values Removed Values Added
References
  • (MISC) https://www.connectwise.com/blog/cybersecurity/the-importance-of-responsible-security-disclosures -
  • (MISC) https://www.huntress.com/blog/clearing-the-air-overblown-claims-of-vulnerabilities-exploits-severity -
Summary ConnectWise Control before 22.9.10032 (formerly known as ScreenConnect) fails to validate user-supplied parameters such as the Bin/ConnectWiseControl.Client.exe h parameter. This results in reflected data and injection of malicious code into a downloaded executable. The executable can be used to execute malicious queries or as a denial-of-service vector. ConnectWise Control before 22.9.10032 (formerly known as ScreenConnect) fails to validate user-supplied parameters such as the Bin/ConnectWiseControl.Client.exe h parameter. This results in reflected data and injection of malicious code into a downloaded executable. The executable can be used to execute malicious queries or as a denial-of-service vector. NOTE: this CVE Record is only about the parameters, such as the h parameter (this CVE Record is not about the separate issue of signed executable files that are supposed to have unique configurations across customers' installations).

23 Feb 2023, 16:49

Type Values Removed Values Added
CPE cpe:2.3:a:connectwise:control:*:*:*:*:*:*:*:*
CWE CWE-74
CVSS v2 : unknown
v3 : unknown
v2 : unknown
v3 : 8.8
References (MISC) https://www.connectwise.com - (MISC) https://www.connectwise.com - Product
References (MISC) https://cybir.com/2022/cve/hijacking-connectwise-control-and-ddos/ - (MISC) https://cybir.com/2022/cve/hijacking-connectwise-control-and-ddos/ - Exploit, Third Party Advisory
First Time Connectwise
Connectwise control

13 Feb 2023, 20:49

Type Values Removed Values Added
New CVE

Information

Published : 2023-02-13 20:15

Updated : 2023-12-10 14:48


NVD link : CVE-2023-25719

Mitre link : CVE-2023-25719

CVE.ORG link : CVE-2023-25719


JSON object : View

Products Affected

connectwise

  • control
CWE
CWE-74

Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')