CVE-2023-44277

Dell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in the CLI. A local low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application's underlying OS, with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:a:dell:powerprotect_data_protection:*:*:*:*:*:*:*:*
OR cpe:2.3:h:dell:dp4400:-:*:*:*:*:*:*:*
cpe:2.3:h:dell:dp5900:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
OR cpe:2.3:a:dell:apex_protection_storage:*:*:*:*:*:*:*:*
cpe:2.3:a:dell:apex_protection_storage:*:*:*:*:*:*:*:*
cpe:2.3:a:dell:powerprotect_data_domain:*:*:*:*:virtual:*:*:*
cpe:2.3:a:dell:powerprotect_data_domain:*:*:*:*:virtual:*:*:*
cpe:2.3:a:dell:powerprotect_data_domain_management_center:*:*:*:*:*:*:*:*
cpe:2.3:a:dell:powerprotect_data_domain_management_center:*:*:*:*:*:*:*:*
cpe:2.3:o:dell:emc_data_domain_os:*:*:*:*:*:*:*:*
cpe:2.3:o:dell:emc_data_domain_os:*:*:*:*:*:*:*:*
cpe:2.3:o:dell:emc_data_domain_os:*:*:*:*:lts2022:*:*:*
cpe:2.3:o:dell:emc_data_domain_os:*:*:*:*:lts2023:*:*:*
cpe:2.3:o:dell:powerprotect_data_domain_management_center:*:*:*:*:lts2022:*:*:*
cpe:2.3:o:dell:powerprotect_data_domain_management_center:*:*:*:*:lts2023:*:*:*
OR cpe:2.3:h:dell:dd3300:-:*:*:*:*:*:*:*
cpe:2.3:h:dell:dd6400:-:*:*:*:*:*:*:*
cpe:2.3:h:dell:dd6900:-:*:*:*:*:*:*:*
cpe:2.3:h:dell:dd9400:-:*:*:*:*:*:*:*
cpe:2.3:h:dell:dd9900:-:*:*:*:*:*:*:*

History

27 Dec 2023, 19:33

Type Values Removed Values Added
CPE cpe:2.3:a:dell:apex_protection_storage:*:*:*:*:*:*:*:*
cpe:2.3:o:dell:emc_data_domain_os:*:*:*:*:*:*:*:*
cpe:2.3:o:dell:emc_data_domain_os:*:*:*:*:lts2023:*:*:*
cpe:2.3:h:dell:dp4400:-:*:*:*:*:*:*:*
cpe:2.3:h:dell:dp5900:-:*:*:*:*:*:*:*
cpe:2.3:o:dell:emc_data_domain_os:*:*:*:*:lts2022:*:*:*
cpe:2.3:a:dell:powerprotect_data_domain_management_center:*:*:*:*:*:*:*:*
cpe:2.3:h:dell:dd6900:-:*:*:*:*:*:*:*
cpe:2.3:h:dell:dd9400:-:*:*:*:*:*:*:*
cpe:2.3:a:dell:powerprotect_data_domain:*:*:*:*:virtual:*:*:*
cpe:2.3:h:dell:dd9900:-:*:*:*:*:*:*:*
cpe:2.3:a:dell:powerprotect_data_protection:*:*:*:*:*:*:*:*
cpe:2.3:o:dell:powerprotect_data_domain_management_center:*:*:*:*:lts2023:*:*:*
cpe:2.3:h:dell:dd6400:-:*:*:*:*:*:*:*
cpe:2.3:o:dell:powerprotect_data_domain_management_center:*:*:*:*:lts2022:*:*:*
cpe:2.3:h:dell:dd3300:-:*:*:*:*:*:*:*
References () https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities - () https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities - Vendor Advisory
First Time Dell dd9900
Dell dp5900
Dell dd3300
Dell powerprotect Data Domain Management Center
Dell apex Protection Storage
Dell dd6900
Dell dd6400
Dell powerprotect Data Domain
Dell emc Data Domain Os
Dell dp4400
Dell dd9400
Dell powerprotect Data Protection
Dell
Summary
  • (es) Dell PowerProtect DD, versiones anteriores a 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contienen una vulnerabilidad de inyección de comandos del sistema operativo en la Interfaz de Línea de Comandos (CLI). Un atacante local con pocos privilegios podría explotar esta vulnerabilidad, lo que llevaría a la ejecución de comandos arbitrarios del sistema operativo en el sistema operativo subyacente de la aplicación, con los privilegios de la aplicación vulnerable. La explotación puede llevar a que un atacante se apodere del sistema.

14 Dec 2023, 15:15

Type Values Removed Values Added
New CVE

Information

Published : 2023-12-14 15:15

Updated : 2023-12-27 19:33


NVD link : CVE-2023-44277

Mitre link : CVE-2023-44277

CVE.ORG link : CVE-2023-44277


JSON object : View

Products Affected

dell

  • powerprotect_data_domain
  • dd9900
  • powerprotect_data_domain_management_center
  • emc_data_domain_os
  • dd3300
  • powerprotect_data_protection
  • dd6400
  • dd6900
  • apex_protection_storage
  • dp4400
  • dd9400
  • dp5900
CWE
CWE-78