CVE-2024-0537

A vulnerability, which was classified as critical, was found in Tenda W9 1.0.0.7(4456). This affects the function setWrlBasicInfo of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250707. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Link Resource
https://github.com/jylsec/vuldb/blob/main/Tenda/W9/2/README.md Broken Link Third Party Advisory
https://vuldb.com/?ctiid.250707 Permissions Required Third Party Advisory VDB Entry
https://vuldb.com/?id.250707 Permissions Required Third Party Advisory VDB Entry
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:tenda:w9_firmware:1.0.0.7\(4456\):*:*:*:*:*:*:*
cpe:2.3:h:tenda:w9:-:*:*:*:*:*:*:*

History

19 Jan 2024, 17:11

Type Values Removed Values Added
First Time Tenda w9
Tenda w9 Firmware
Tenda
CVSS v2 : 9.0
v3 : 8.8
v2 : 9.0
v3 : 9.8
CPE cpe:2.3:h:tenda:w9:-:*:*:*:*:*:*:*
cpe:2.3:o:tenda:w9_firmware:1.0.0.7\(4456\):*:*:*:*:*:*:*
References () https://github.com/jylsec/vuldb/blob/main/Tenda/W9/2/README.md - () https://github.com/jylsec/vuldb/blob/main/Tenda/W9/2/README.md - Broken Link, Third Party Advisory
References () https://vuldb.com/?ctiid.250707 - () https://vuldb.com/?ctiid.250707 - Permissions Required, Third Party Advisory, VDB Entry
References () https://vuldb.com/?id.250707 - () https://vuldb.com/?id.250707 - Permissions Required, Third Party Advisory, VDB Entry
CWE CWE-787

16 Jan 2024, 13:56

Type Values Removed Values Added
Summary
  • (es) Una vulnerabilidad fue encontrada en Tenda W9 1.0.0.7(4456) y clasificada como crítica. Esto afecta a la función setWrlBasicInfo del componente httpd. La manipulación del argumento ssidIndex provoca un desbordamiento de búfer en la región stack de la memoria. Es posible iniciar el ataque de forma remota. La explotación ha sido divulgada al público y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-250707. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera

15 Jan 2024, 04:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-01-15 04:15

Updated : 2024-04-11 01:24


NVD link : CVE-2024-0537

Mitre link : CVE-2024-0537

CVE.ORG link : CVE-2024-0537


JSON object : View

Products Affected

tenda

  • w9
  • w9_firmware
CWE
CWE-787

Out-of-bounds Write

CWE-121

Stack-based Buffer Overflow