CVE-2024-0540

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. Affected is the function formOfflineSet of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-250710 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Link Resource
https://github.com/jylsec/vuldb/blob/main/Tenda/W9/5/README.md Broken Link Third Party Advisory
https://vuldb.com/?ctiid.250710 Permissions Required Third Party Advisory VDB Entry
https://vuldb.com/?id.250710 Permissions Required Third Party Advisory VDB Entry
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:tenda:w9_firmware:1.0.0.7\(4456\):*:*:*:*:*:*:*
cpe:2.3:h:tenda:w9:-:*:*:*:*:*:*:*

History

19 Jan 2024, 17:10

Type Values Removed Values Added
CPE cpe:2.3:h:tenda:w9:-:*:*:*:*:*:*:*
cpe:2.3:o:tenda:w9_firmware:1.0.0.7\(4456\):*:*:*:*:*:*:*
CWE CWE-787
CVSS v2 : 6.5
v3 : 6.3
v2 : 6.5
v3 : 9.8
References () https://github.com/jylsec/vuldb/blob/main/Tenda/W9/5/README.md - () https://github.com/jylsec/vuldb/blob/main/Tenda/W9/5/README.md - Broken Link, Third Party Advisory
References () https://vuldb.com/?ctiid.250710 - () https://vuldb.com/?ctiid.250710 - Permissions Required, Third Party Advisory, VDB Entry
References () https://vuldb.com/?id.250710 - () https://vuldb.com/?id.250710 - Permissions Required, Third Party Advisory, VDB Entry
First Time Tenda w9
Tenda w9 Firmware
Tenda

16 Jan 2024, 13:56

Type Values Removed Values Added
Summary
  • (es) Se encontró una vulnerabilidad en Tenda W9 1.0.0.7(4456). Ha sido clasificada como crítica. La función formOfflineSet del componente httpd es afectada por esta vulnerabilidad. La manipulación del argumento ssidIndex provoca un desbordamiento de búfer en la región stack de la memoria. Es posible lanzar el ataque de forma remota. La explotación ha sido divulgada al público y puede utilizarse. VDB-250710 es el identificador asignado a esta vulnerabilidad. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera

15 Jan 2024, 05:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-01-15 05:15

Updated : 2024-04-11 01:24


NVD link : CVE-2024-0540

Mitre link : CVE-2024-0540

CVE.ORG link : CVE-2024-0540


JSON object : View

Products Affected

tenda

  • w9
  • w9_firmware
CWE
CWE-787

Out-of-bounds Write

CWE-121