Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
Total 1751 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2019-15681 4 Canonical, Debian, Libvnc Project and 1 more 15 Ubuntu Linux, Debian Linux, Libvncserver and 12 more 2023-12-10 5.0 MEDIUM 7.5 HIGH
LibVNC commit before d01e1bb4246323ba6fcee3b82ef1faa9b1dac82a contains a memory leak (CWE-655) in VNC server code, which allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appear to be exploitable via network connectivity. These vulnerabilities have been fixed in commit d01e1bb4246323ba6fcee3b82ef1faa9b1dac82a.
CVE-2019-13929 1 Siemens 1 Simatic It Uadm 2023-12-10 4.0 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in SIMATIC IT UADM (All versions < V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13946 1 Siemens 101 Dk Standard Ethernet Controller, Ek-ertec 200, Ek-ertec 200 Firmware and 98 more 2023-12-10 7.8 HIGH 7.5 HIGH
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device.
CVE-2019-19646 5 Netapp, Oracle, Siemens and 2 more 6 Cloud Backup, Ontap Select Deploy Administration Utility, Mysql Workbench and 3 more 2023-12-10 7.5 HIGH 9.8 CRITICAL
pragma.c in SQLite through 3.30.1 mishandles NOT NULL in an integrity_check PRAGMA command in certain cases of generated columns.
CVE-2019-10934 1 Siemens 1 Totally Integrated Automation Portal 2023-12-10 7.2 HIGH 7.8 HIGH
A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions < V16 Update 6), TIA Portal V17 (All versions < V17 Update 4). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-18283 1 Siemens 1 Sppa-t3000 Application Server 2023-12-10 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can gain remote code execution by sending specifically crafted objects to one of its functions. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-19603 5 Apache, Netapp, Oracle and 2 more 6 Guacamole, Cloud Backup, Ontap Select Deploy Administration Utility and 3 more 2023-12-10 5.0 MEDIUM 7.5 HIGH
SQLite 3.30.1 mishandles certain SELECT statements with a nonexistent VIEW, leading to an application crash.
CVE-2018-16417 2 Arubanetworks, Siemens 3 Instant, W1750d, W1750d Firmware 2023-12-10 5.0 MEDIUM 7.5 HIGH
Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection.
CVE-2019-13931 1 Siemens 1 Xhq 2023-12-10 3.5 LOW 5.4 MEDIUM
A vulnerability has been identified in XHQ (All versions < V6.0.0.2). The web interface could allow for an an attacker to craft the input in a form that is not expected, causing the application to behave in unexpected ways for legitimate users. Successful exploitation requires for an attacker to be authenticated to the web interface. A successful attack could cause the application to have unexpected behavior. This could allow the attacker to modify contents of the web application. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-10940 1 Siemens 1 Sinema Server 2023-12-10 9.0 HIGH 9.9 CRITICAL
A vulnerability has been identified in SINEMA Server (All versions < V14.0 SP2 Update 1). Incorrect session validation could allow an attacker with a valid session, with low privileges, to perform firmware updates and other administrative operations on connected devices. The security vulnerability could be exploited by an attacker with network access to the affected system. An attacker must have access to a low privileged account in order to exploit the vulnerability. An attacker could use the vulnerability to compromise confidentiality, integrity, and availability of the affected system and underlying components. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-16905 3 Netapp, Openbsd, Siemens 7 Cloud Backup, Steelstore Cloud Integrated Storage, Openssh and 4 more 2023-12-10 4.4 MEDIUM 7.8 HIGH
OpenSSH 7.7 through 7.9 and 8.x before 8.1, when compiled with an experimental key type, has a pre-authentication integer overflow if a client or server is configured to use a crafted XMSS key. This leads to memory corruption and local code execution because of an error in the XMSS key parsing algorithm. NOTE: the XMSS implementation is considered experimental in all released OpenSSH versions, and there is no supported way to enable it when building portable OpenSSH.
CVE-2019-19925 8 Debian, Netapp, Opensuse and 5 more 12 Debian Linux, Cloud Backup, Backports Sle and 9 more 2023-12-10 5.0 MEDIUM 7.5 HIGH
zipfileUpdate in ext/misc/zipfile.c in SQLite 3.30.1 mishandles a NULL pathname during an update of a ZIP archive.
CVE-2019-19956 7 Canonical, Debian, Fedoraproject and 4 more 12 Ubuntu Linux, Debian Linux, Fedora and 9 more 2023-12-10 5.0 MEDIUM 7.5 HIGH
xmlParseBalancedChunkMemoryRecover in parser.c in libxml2 before 2.9.10 has a memory leak related to newDoc->oldNs.
CVE-2019-18326 1 Siemens 1 Sppa-t3000 Ms3000 Migration Server 2023-12-10 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18327, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13925 1 Siemens 8 Scalance S602, Scalance S602 Firmware, Scalance S612 and 5 more 2023-12-10 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server.
CVE-2019-18292 1 Siemens 1 Sppa-t3000 Ms3000 Migration Server 2023-12-10 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290, CVE-2019-18291, CVE-2019-18294, CVE-2019-18298, CVE-2019-18299, CVE-2019-18300, CVE-2019-18301, CVE-2019-18302, CVE-2019-18303, CVE-2019-18304, CVE-2019-18305, CVE-2019-18306, and CVE-2019-18307. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-18314 1 Siemens 1 Sppa-t3000 Application Server 2023-12-10 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted objects via RMI. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-18319 1 Siemens 1 Sppa-t3000 Application Server 2023-12-10 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could cause a Denial-of-Service condition by sending specifically crafted objects via RMI. This vulnerability is independent from CVE-2019-18317 and CVE-2019-18318. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-18332 1 Siemens 1 Sppa-t3000 Application Server 2023-12-10 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to directory listings of the server by sending specifically crafted packets to 80/tcp, 8095/tcp or 8080/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2016-2031 2 Arubanetworks, Siemens 5 Airwave, Aruba Instant, Arubaos and 2 more 2023-12-10 7.5 HIGH 9.8 CRITICAL
Multiple vulnerabilities exists in Aruba Instate before 4.1.3.0 and 4.2.3.1 due to insufficient validation of user-supplied input and insufficient checking of parameters, which could allow a malicious user to bypass security restrictions, obtain sensitive information, perform unauthorized actions and execute arbitrary code.