Vulnerabilities (CVE)

Filtered by vendor Emerson Subscribe
Filtered by product X-stream Enhanced Xegk
Total 7 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-27463 1 Emerson 8 X-stream Enhanced Xefd, X-stream Enhanced Xefd Firmware, X-stream Enhanced Xegk and 5 more 2023-12-10 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected applications utilize persistent cookies where the session cookie attribute is not properly invalidated, allowing an attacker to intercept the cookies and gain access to sensitive information.
CVE-2021-27459 1 Emerson 8 X-stream Enhanced Xefd, X-stream Enhanced Xefd Firmware, X-stream Enhanced Xegk and 5 more 2023-12-10 7.5 HIGH 9.8 CRITICAL
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The webserver of the affected products allows unvalidated files to be uploaded, which an attacker could utilize to execute arbitrary code.
CVE-2021-27457 1 Emerson 8 X-stream Enhanced Xefd, X-stream Enhanced Xefd Firmware, X-stream Enhanced Xegk and 5 more 2023-12-10 5.0 MEDIUM 7.5 HIGH
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected products utilize a weak encryption algorithm for storage of sensitive data, which may allow an attacker to more easily obtain credentials used for access.
CVE-2021-27461 1 Emerson 8 X-stream Enhanced Xefd, X-stream Enhanced Xefd Firmware, X-stream Enhanced Xegk and 5 more 2023-12-10 5.0 MEDIUM 7.5 HIGH
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected webserver applications allow access to stored data that can be obtained by using specially crafted URLs.
CVE-2021-27465 1 Emerson 8 X-stream Enhanced Xefd, X-stream Enhanced Xefd Firmware, X-stream Enhanced Xegk and 5 more 2023-12-10 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected applications do not validate webpage input, which could allow an attacker to inject arbitrary HTML code into a webpage. This would allow an attacker to modify the page and display incorrect or undesirable data.
CVE-2021-27467 1 Emerson 8 X-stream Enhanced Xefd, X-stream Enhanced Xefd Firmware, X-stream Enhanced Xegk and 5 more 2023-12-10 5.8 MEDIUM 6.1 MEDIUM
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected product’s web interface allows an attacker to route click or keystroke to another page provided by the attacker to gain unauthorized access to sensitive information.
CVE-2020-27254 1 Emerson 8 X-stream Enhanced Xefd, X-stream Enhanced Xefd Firmware, X-stream Enhanced Xegk and 5 more 2023-12-10 5.0 MEDIUM 7.5 HIGH
Emerson Rosemount X-STREAM Gas AnalyzerX-STREAM enhanced XEGP, XEGK, XEFD, XEXF – all revisions, The affected products are vulnerable to improper authentication for accessing log and backup data, which could allow an attacker with a specially crafted URL to obtain access to sensitive information.