Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
Total 1751 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2013-4780 1 Siemens 2 Enterprise Openscape Branch, Openscape Session Border Controller 2023-12-10 7.8 HIGH N/A
core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to read arbitrary files via unspecified vectors.
CVE-2012-4698 1 Siemens 4 Ros, Rox I Os, Rox Ii Os and 1 more 2023-12-10 4.3 MEDIUM N/A
Siemens RuggedCom Rugged Operating System (ROS) before 3.12, ROX I OS through 1.14.5, ROX II OS through 2.3.0, and RuggedMax OS through 4.2.1.4621.22 use hardcoded private keys for SSL and SSH communication, which makes it easier for man-in-the-middle attackers to spoof servers and decrypt network traffic by leveraging the availability of these keys within ROS files at all customer installations.
CVE-2011-4515 1 Siemens 1 Wincc Tia Portal 2023-12-10 4.6 MEDIUM N/A
Siemens WinCC (TIA Portal) 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable files, which allows local users to obtain sensitive information by leveraging (1) physical access or (2) Sm@rt Server access.
CVE-2012-3040 1 Siemens 18 Simatic S7-1200, Simatic S7-1200 Cpu 1211c, Simatic S7-1200 Cpu 1211c Firmware and 15 more 2023-12-10 4.3 MEDIUM N/A
Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI.
CVE-2013-3959 1 Siemens 2 Simatic Pcs7, Wincc 2023-12-10 4.0 MEDIUM N/A
The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters.
CVE-2013-0677 1 Siemens 2 Simatic Pcs7, Wincc 2023-12-10 5.8 MEDIUM N/A
The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file.
CVE-2012-2441 1 Siemens 1 Ruggedcom Rugged Operating System 2023-12-10 8.5 HIGH N/A
RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password derived from the MAC Address field in a banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) SSH or (2) HTTPS session, a different vulnerability than CVE-2012-1803.
CVE-2013-6840 1 Siemens 1 Comos 2023-12-10 6.9 MEDIUM N/A
Siemens COMOS before 9.2.0.8.1, 10.0 before 10.0.3.1.40, and 10.1 before 10.1.0.0.2 allows local users to gain database privileges via unspecified vectors.
CVE-2013-0672 1 Siemens 1 Wincc Tia Portal 2023-12-10 3.5 LOW N/A
Cross-site scripting (XSS) vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to inject arbitrary web script or HTML via unspecified data.
CVE-2011-4530 1 Siemens 1 Automation License Manager 2023-12-10 5.0 MEDIUM N/A
Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 does not properly copy fields obtained from clients, which allows remote attackers to cause a denial of service (exception and daemon crash) via long fields, as demonstrated by fields to the (1) open_session->workstation->NAME or (2) grant->VERSION function.
CVE-2011-4511 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2023-12-10 4.3 MEDIUM N/A
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510.
CVE-2011-4510 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2023-12-10 4.3 MEDIUM N/A
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511.
CVE-2011-4056 1 Siemens 1 Tecnomatix Factorylink 2023-12-10 5.8 MEDIUM N/A
An unspecified ActiveX control in ActBar.ocx in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to create or overwrite arbitrary files via the save method.
CVE-2011-3389 9 Canonical, Debian, Google and 6 more 17 Ubuntu Linux, Debian Linux, Chrome and 14 more 2023-12-10 4.3 MEDIUM N/A
The SSL protocol, as used in certain configurations in Microsoft Windows and Microsoft Internet Explorer, Mozilla Firefox, Google Chrome, Opera, and other products, encrypts data by using CBC mode with chained initialization vectors, which allows man-in-the-middle attackers to obtain plaintext HTTP headers via a blockwise chosen-boundary attack (BCBA) on an HTTPS session, in conjunction with JavaScript code that uses (1) the HTML5 WebSocket API, (2) the Java URLConnection API, or (3) the Silverlight WebClient API, aka a "BEAST" attack.
CVE-2011-4531 1 Siemens 1 Automation License Manager 2023-12-10 5.0 MEDIUM N/A
Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allows remote attackers to cause a denial of service (NULL pointer dereference and daemon crash) via crafted content in a (1) get_target_ocx_param or (2) send_target_ocx_param command.
CVE-2011-4878 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2023-12-10 7.8 HIGH N/A
Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI.
CVE-2011-4508 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2023-12-10 9.3 HIGH N/A
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie.
CVE-2011-4876 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2023-12-10 9.3 HIGH N/A
Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string.
CVE-2011-4875 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2023-12-10 9.3 HIGH N/A
Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings.
CVE-2011-4055 1 Siemens 1 Tecnomatix Factorylink 2023-12-10 9.3 HIGH N/A
Buffer overflow in the WebClient ActiveX control in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to execute arbitrary code via a long string in a parameter associated with the location URL.