CVE-2023-24995 1 Siemens 1 Tecnomatix Plant Simulation 2023-12-10 N/A 7.8 HIGH
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19817)
CVE-2023-24993 1 Siemens 1 Tecnomatix Plant Simulation 2023-12-10 N/A 7.8 HIGH
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19815)
CVE-2023-24996 1 Siemens 1 Tecnomatix Plant Simulation 2023-12-10 N/A 7.8 HIGH
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19818)
CVE-2023-24988 1 Siemens 1 Tecnomatix Plant Simulation 2023-12-10 N/A 7.8 HIGH
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19810)
CVE-2023-27398 1 Siemens 1 Tecnomatix Plant Simulation 2023-12-10 N/A 7.8 HIGH
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20304)
CVE-2021-27398 1 Siemens 1 Tecnomatix Plant Simulation 2023-12-10 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27396. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13290)
CVE-2021-27397 1 Siemens 1 Tecnomatix Plant Simulation 2023-12-10 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13287)
CVE-2021-27396 1 Siemens 1 Tecnomatix Plant Simulation 2023-12-10 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27398. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13279)