Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Total 739 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-38932 1 Tenda 8 F1202, F1202 Firmware, Fh1202 and 5 more 2023-12-10 N/A 9.8 CRITICAL
Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter in the SafeEmailFilter function.
CVE-2023-42320 1 Tenda 2 Ac10, Ac10 Firmware 2023-12-10 N/A 9.8 CRITICAL
Buffer Overflow vulnerability in Tenda AC10V4 v.US_AC10V4.0si_V16.03.10.13_cn_TDC01 allows a remote attacker to cause a denial of service via the mac parameter in the GetParentControlInfo function.
CVE-2023-40801 1 Tenda 2 Ac23, Ac23 Firmware 2023-12-10 N/A 8.8 HIGH
The sub_451784 function does not validate the parameters entered by the user, resulting in a stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn
CVE-2023-38933 1 Tenda 18 Ac10, Ac10 Firmware, Ac1206 and 15 more 2023-12-10 N/A 9.8 CRITICAL
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
CVE-2023-37714 1 Tenda 8 Ac7, Ac7 Firmware, F1202 and 5 more 2023-12-10 N/A 9.8 CRITICAL
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic.
CVE-2023-41560 1 Tenda 2 Ac9, Ac9 Firmware 2023-12-10 N/A 9.8 CRITICAL
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg.
CVE-2023-40898 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2023-12-10 N/A 9.8 CRITICAL
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter timeZone at /goform/SetSysTimeCfg.
CVE-2023-41558 1 Tenda 2 Ac7, Ac7 Firmware 2023-12-10 N/A 9.8 CRITICAL
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg.
CVE-2023-39827 1 Tenda 2 A18, A18 Firmware 2023-12-10 N/A 7.5 HIGH
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the rule_info parameter in the formAddMacfilterRule function.
CVE-2023-40901 1 Tenda 2 Ac10v4, Ac10v4 Firmware 2023-12-10 N/A 9.8 CRITICAL
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg.
CVE-2023-40837 1 Tenda 2 Ac6, Ac6 Firmware 2023-12-10 N/A 9.8 CRITICAL
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_ADD50' contains a command execution vulnerability. In the "formSetIptv" function, obtaining the "list" and "vlanId" fields, unfiltered passing these two fields as parameters to the "sub_ADD50" function to execute commands.
CVE-2023-38929 1 Tenda 2 4g300, 4g300 Firmware 2023-12-10 N/A 9.8 CRITICAL
Tenda 4G300 v1.01.42 was discovered to contain a stack overflow via the page parameter at /VirtualSer.
CVE-2023-38939 1 Tenda 4 F1202, F1202 Firmware, Fh1202 and 1 more 2023-12-10 N/A 9.8 CRITICAL
Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the mit_ssid parameter in the formWrlsafeset function.
CVE-2023-39673 1 Tenda 2 Ac15, Ac15 Firmware 2023-12-10 N/A 9.8 CRITICAL
Tenda AC15 V1.0BR_V15.03.05.18_multi_TD01 was discovered to contain a buffer overflow via the function FUN_00010e34().
CVE-2023-41556 1 Tenda 6 Ac5, Ac5 Firmware, Ac7 and 3 more 2023-12-10 N/A 9.8 CRITICAL
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind.
CVE-2023-38931 1 Tenda 16 Ac10, Ac10 Firmware, Ac1206 and 13 more 2023-12-10 N/A 9.8 CRITICAL
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function.
CVE-2023-4498 1 Tenda 2 N300, N300 Firmware 2023-12-10 N/A 5.3 MEDIUM
Tenda N300 Wireless N VDSL2 Modem Router allows unauthenticated access to pages that in turn should be accessible to authenticated users only
CVE-2023-41559 1 Tenda 6 Ac5, Ac5 Firmware, Ac7 and 3 more 2023-12-10 N/A 9.8 CRITICAL
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting.
CVE-2023-37716 1 Tenda 14 Ac10, Ac10 Firmware, Ac1206 and 11 more 2023-12-10 N/A 9.8 CRITICAL
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.
CVE-2023-37717 1 Tenda 14 Ac10, Ac10 Firmware, Ac1206 and 11 more 2023-12-10 N/A 9.8 CRITICAL
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.