Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Filtered by product Ac9
Total 60 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-24543 1 Tenda 2 Ac9, Ac9 Firmware 2024-02-14 N/A 9.8 CRITICAL
Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data.
CVE-2023-38823 1 Tenda 8 Ac18, Ac18 Firmware, Ac19 and 5 more 2023-12-10 N/A 9.8 CRITICAL
Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd.
CVE-2023-38933 1 Tenda 18 Ac10, Ac10 Firmware, Ac1206 and 15 more 2023-12-10 N/A 9.8 CRITICAL
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
CVE-2023-41560 1 Tenda 2 Ac9, Ac9 Firmware 2023-12-10 N/A 9.8 CRITICAL
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg.
CVE-2023-41556 1 Tenda 6 Ac5, Ac5 Firmware, Ac7 and 3 more 2023-12-10 N/A 9.8 CRITICAL
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind.
CVE-2023-41559 1 Tenda 6 Ac5, Ac5 Firmware, Ac7 and 3 more 2023-12-10 N/A 9.8 CRITICAL
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting.
CVE-2023-37716 1 Tenda 14 Ac10, Ac10 Firmware, Ac1206 and 11 more 2023-12-10 N/A 9.8 CRITICAL
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.
CVE-2023-37717 1 Tenda 14 Ac10, Ac10 Firmware, Ac1206 and 11 more 2023-12-10 N/A 9.8 CRITICAL
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.
CVE-2023-38935 1 Tenda 10 Ac10, Ac10 Firmware, Ac1206 and 7 more 2023-12-10 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function.
CVE-2023-38937 1 Tenda 14 Ac10, Ac10 Firmware, Ac1206 and 11 more 2023-12-10 N/A 9.8 CRITICAL
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.
CVE-2023-41561 1 Tenda 4 Ac5, Ac5 Firmware, Ac9 and 1 more 2023-12-10 N/A 9.8 CRITICAL
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg.
CVE-2023-38930 1 Tenda 10 Ac5, Ac5 Firmware, Ac7 and 7 more 2023-12-10 N/A 9.8 CRITICAL
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
CVE-2023-41562 1 Tenda 6 Ac5, Ac5 Firmware, Ac7 and 3 more 2023-12-10 N/A 9.8 CRITICAL
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet.
CVE-2023-41553 1 Tenda 4 Ac5, Ac5 Firmware, Ac9 and 1 more 2023-12-10 N/A 9.8 CRITICAL
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg.
CVE-2023-41563 1 Tenda 4 Ac5, Ac5 Firmware, Ac9 and 1 more 2023-12-10 N/A 9.8 CRITICAL
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo.
CVE-2023-41554 1 Tenda 2 Ac9, Ac9 Firmware 2023-12-10 N/A 9.8 CRITICAL
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet.
CVE-2023-41552 1 Tenda 4 Ac7, Ac7 Firmware, Ac9 and 1 more 2023-12-10 N/A 9.8 CRITICAL
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set.
CVE-2023-38936 1 Tenda 18 Ac10, Ac10 Firmware, Ac1206 and 15 more 2023-12-10 N/A 9.8 CRITICAL
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
CVE-2022-36570 1 Tenda 2 Ac9, Ac9 Firmware 2023-12-10 N/A 7.2 HIGH
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the time parameter at /goform/SetLEDCfg.
CVE-2022-36569 1 Tenda 2 Ac9, Ac9 Firmware 2023-12-10 N/A 8.8 HIGH
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the deviceList parameter at /goform/setMacFilterCfg.