Vulnerabilities (CVE)

Filtered by vendor Juniper Subscribe
Filtered by product Ex2300-24mp
Total 12 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-36845 1 Juniper 92 Ex2200, Ex2200-c, Ex2200-vc and 89 more 2024-02-02 N/A 9.8 CRITICAL
A PHP External Variable Modification vulnerability in J-Web of Juniper Networks Junos OS on EX Series and SRX Series allows an unauthenticated, network-based attacker to remotely execute code. Using a crafted request which sets the variable PHPRC an attacker is able to modify the PHP execution environment allowing the injection und execution of code. This issue affects Juniper Networks Junos OS on EX Series and SRX Series: * All versions prior to 20.4R3-S9; * 21.1 versions 21.1R1 and later; * 21.2 versions prior to 21.2R3-S7; * 21.3 versions prior to 21.3R3-S5; * 21.4 versions prior to 21.4R3-S5; * 22.1 versions prior to 22.1R3-S4; * 22.2 versions prior to 22.2R3-S2; * 22.3 versions prior to 22.3R2-S2, 22.3R3-S1; * 22.4 versions prior to 22.4R2-S1, 22.4R3; * 23.2 versions prior to 23.2R1-S1, 23.2R2.
CVE-2024-21620 1 Juniper 105 Ex2200, Ex2200-c, Ex2200-vc and 102 more 2024-02-01 N/A 6.1 MEDIUM
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in J-Web of Juniper Networks Junos OS on SRX Series and EX Series allows an attacker to construct a URL that when visited by another user enables the attacker to execute commands with the target's permissions, including an administrator. A specific invocation of the emit_debug_note method in webauth_operation.php will echo back the data it receives. This issue affects Juniper Networks Junos OS on SRX Series and EX Series: * All versions earlier than 20.4R3-S10; * 21.2 versions earlier than 21.2R3-S8; * 21.4 versions earlier than 21.4R3-S6; * 22.1 versions earlier than 22.1R3-S5; * 22.2 versions earlier than 22.2R3-S3; * 22.3 versions earlier than 22.3R3-S2; * 22.4 versions earlier than 22.4R3-S1; * 23.2 versions earlier than 23.2R2; * 23.4 versions earlier than 23.4R2.
CVE-2024-21619 1 Juniper 105 Ex2200, Ex2200-c, Ex2200-vc and 102 more 2024-01-31 N/A 7.5 HIGH
A Missing Authentication for Critical Function vulnerability combined with a Generation of Error Message Containing Sensitive Information vulnerability in J-Web of Juniper Networks Junos OS on SRX Series and EX Series allows an unauthenticated, network-based attacker to access sensitive system information. When a user logs in, a temporary file which contains the configuration of the device (as visible to that user) is created in the /cache folder. An unauthenticated attacker can then attempt to access such a file by sending a specific request to the device trying to guess the name of such a file. Successful exploitation will reveal configuration information. This issue affects Juniper Networks Junos OS on SRX Series and EX Series: * All versions earlier than 20.4R3-S9; * 21.2 versions earlier than 21.2R3-S7; * 21.3 versions earlier than 21.3R3-S5; * 21.4 versions earlier than 21.4R3-S6; * 22.1 versions earlier than 22.1R3-S5; * 22.2 versions earlier than 22.2R3-S3; * 22.3 versions earlier than 22.3R3-S2; * 22.4 versions earlier than 22.4R3; * 23.2 versions earlier than 23.2R1-S2, 23.2R2.
CVE-2023-36851 1 Juniper 92 Ex2200, Ex2200-c, Ex2200-vc and 89 more 2024-01-25 N/A 5.3 MEDIUM
A Missing Authentication for Critical Function vulnerability in Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based attacker to cause limited impact to the file system integrity. With a specific request to webauth_operation.php that doesn't require authentication, an attacker is able to upload and download arbitrary files via J-Web, leading to a loss of integrity or confidentiality, which may allow chaining to other vulnerabilities. This issue affects Juniper Networks Junos OS on SRX Series: * 21.2 versions prior to 21.2R3-S8; * 21.4 versions prior to 21.4R3-S6; * 22.1 versions prior to 22.1R3-S5; * 22.2 versions prior to 22.2R3-S3; * 22.3 versions prior to 22.3R3-S2; * 22.4 versions prior to 22,4R2-S2, 22.4R3; * 23.2 versions prior to 23.2R1-S2, 23.2R2.
CVE-2023-44203 1 Juniper 26 Ex2300, Ex2300-24mp, Ex2300-24p and 23 more 2023-12-10 N/A 6.5 MEDIUM
An Improper Check or Handling of Exceptional Conditions vulnerability in the Packet Forwarding Engine (pfe) of Juniper Networks Junos OS on QFX5000 Series, EX2300, EX3400, EX4100, EX4400 and EX4600 allows a adjacent attacker to send specific traffic, which leads to packet flooding, resulting in a Denial of Service (DoS). When a specific IGMP packet is received in an isolated VLAN, it is duplicated to all other ports under the primary VLAN, which causes a flood. This issue affects QFX5000 series, EX2300, EX3400, EX4100, EX4400 and EX4600 platforms only. This issue affects Juniper Junos OS on on QFX5000 Series, EX2300, EX3400, EX4100, EX4400 and EX4600: * All versions prior to 20.4R3-S5; * 21.1 versions prior to 21.1R3-S4; * 21.2 versions prior to 21.2R3-S3; * 21.3 versions prior to 21.3R3-S5; * 21.4 versions prior to 21.4R3-S2; * 22.1 versions prior to 22.1R3; * 22.2 versions prior to 22.2R3; * 22.3 versions prior to 22.3R2.
CVE-2023-36847 1 Juniper 92 Ex2200, Ex2200-c, Ex2200-vc and 89 more 2023-12-10 N/A 5.3 MEDIUM
A Missing Authentication for Critical Function vulnerability in Juniper Networks Junos OS on EX Series allows an unauthenticated, network-based attacker to cause limited impact to the file system integrity. With a specific request to installAppPackage.php that doesn't require authentication an attacker is able to upload arbitrary files via J-Web, leading to a loss of integrity for a certain part of the file system, which may allow chaining to other vulnerabilities. This issue affects Juniper Networks Junos OS on EX Series: * All versions prior to 20.4R3-S8; * 21.1 versions 21.1R1 and later; * 21.2 versions prior to 21.2R3-S6; * 21.3 versions prior to 21.3R3-S5; * 21.4 versions prior to 21.4R3-S4; * 22.1 versions prior to 22.1R3-S3; * 22.2 versions prior to 22.2R3-S1; * 22.3 versions prior to 22.3R2-S2, 22.3R3; * 22.4 versions prior to 22.4R2-S1, 22.4R3.
CVE-2023-36846 1 Juniper 92 Ex2200, Ex2200-c, Ex2200-vc and 89 more 2023-12-10 N/A 5.3 MEDIUM
A Missing Authentication for Critical Function vulnerability in Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based attacker to cause limited impact to the file system integrity. With a specific request to user.php that doesn't require authentication an attacker is able to upload arbitrary files via J-Web, leading to a loss of integrity for a certain  part of the file system, which may allow chaining to other vulnerabilities. This issue affects Juniper Networks Junos OS on SRX Series: * All versions prior to 20.4R3-S8; * 21.1 versions 21.1R1 and later; * 21.2 versions prior to 21.2R3-S6; * 21.3 versions prior to 21.3R3-S5; * 21.4 versions prior to 21.4R3-S5; * 22.1 versions prior to 22.1R3-S3; * 22.2 versions prior to 22.2R3-S2; * 22.3 versions prior to 22.3R2-S2, 22.3R3; * 22.4 versions prior to 22.4R2-S1, 22.4R3.
CVE-2023-36844 1 Juniper 92 Ex2200, Ex2200-c, Ex2200-vc and 89 more 2023-12-10 N/A 5.3 MEDIUM
A PHP External Variable Modification vulnerability in J-Web of Juniper Networks Junos OS on EX Series allows an unauthenticated, network-based attacker to control certain, important environment variables. Using a crafted request an attacker is able to modify certain PHP environment variables leading to partial loss of integrity, which may allow chaining to other vulnerabilities. This issue affects Juniper Networks Junos OS on EX Series: * All versions prior to 20.4R3-S9; * 21.1 versions 21.1R1 and later; * 21.2 versions prior to 21.2R3-S7; * 21.3 versions prior to 21.3R3-S5; * 21.4 versions prior to 21.4R3-S5; * 22.1 versions prior to 22.1R3-S4; * 22.2 versions prior to 22.2R3-S2; * 22.3 versions prior to 22.3R3-S1; * 22.4 versions prior to 22.4R2-S2, 22.4R3; * 23.2 versions prior to 23.2R1-S1, 23.2R2.
CVE-2022-22234 1 Juniper 11 Ex2300, Ex2300-24mp, Ex2300-24p and 8 more 2023-12-10 N/A 5.5 MEDIUM
An Improper Preservation of Consistency Between Independent Representations of Shared State vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows a locally authenticated attacker with low privileges to cause a Denial of Service (DoS). If the device is very busy for example while executing a series of show commands on the CLI one or more SFPs might not be detected anymore. The system then changes its state to "unplugged" which is leading to traffic impact and at least a partial DoS. Once the system is less busy the port states return to their actual value. Indicators of compromise are log messages about unplugged SFPs and corresponding syspld messages without any physical or environmental cause. These can be checked by issuing the following commands: user@device# show log messages | match unplugged %PFE-6: fpc0 sfp-0/1/2 SFP unplugged %PFE-6: fpc0 sfp-0/1/3 SFP unplugged The following log messages will also be seen when this issue happens: fpc0 Error tvp_drv_syspld_read: syspld read failed for address <address> fpc0 Error[-1]:tvp_optics_presence_get - Syspld read failed for port <pic/port> fpc0 optics pres failed(-1) for pic <pic> port <port> fpc0 tvp_drv_syspld_read: i2c access retry count 200 This issue affects Juniper Networks Junos OS on EX2300 Series, EX3400 Series: All versions prior to 18.4R3-S11; 19.1 versions prior to 19.1R3-S9; 19.2 versions prior to 19.2R1-S9, 19.2R3-S5; 19.3 versions prior to 19.3R3-S6; 19.4 versions prior to 19.4R2-S7, 19.4R3-S8; 20.1 versions prior to 20.1R3-S4; 20.2 versions prior to 20.2R3-S4; 20.3 versions prior to 20.3R3-S4; 20.4 versions prior to 20.4R3-S3; 21.1 versions prior to 21.1R3-S1; 21.2 versions prior to 21.2R3; 21.3 versions prior to 21.3R2; 21.4 versions prior to 21.4R2.
CVE-2022-22180 1 Juniper 11 Ex2300, Ex2300-24mp, Ex2300-24p and 8 more 2023-12-10 5.0 MEDIUM 7.5 HIGH
An Improper Check for Unusual or Exceptional Conditions vulnerability in the processing of specific IPv6 packets on certain EX Series devices may lead to exhaustion of DMA memory causing a Denial of Service (DoS). Over time, exploitation of this vulnerability may cause traffic to stop being forwarded, or a crash of the fxpc process. An indication of the issue occurring may be observed through the following log messages: Sep 13 17:14:59 hostname : %PFE-3: fpc0 (buf alloc) failed allocating packet buffer Sep 13 17:14:59 hostname : %PFE-7: fpc0 brcm_pkt_buf_alloc:393 (buf alloc) failed allocating packet buffer When Packet DMA heap utilization reaches 99%, the system will become unstable. Packet DMA heap utilization can be monitored using the command: user@junos# request pfe execute target fpc0 timeout 30 command "show heap" ID Base Total(b) Free(b) Used(b) % Name -- ---------- ----------- ----------- ----------- --- ----------- 0 213301a8 536870488 387228840 149641648 27 Kernel 1 91800000 8388608 3735120 4653488 55 DMA 2 92000000 75497472 74452192 1045280 1 PKT DMA DESC 3 d330000 335544320 257091400 78452920 23 Bcm_sdk 4 96800000 184549376 2408 184546968 99 Packet DMA <<<< 5 903fffe0 20971504 20971504 0 0 Blob This issue affects: Juniper Networks Junos OS 18.4 versions prior to 18.4R2-S10, 18.4R3-S10 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.1 versions prior to 19.1R3-S7 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.3 versions prior to 19.3R3-S5 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.4 versions prior to 19.4R3-S7 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.1 versions prior to 20.1R3-S3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.2 versions prior to 20.2R3-S3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.3 versions prior to 20.3R3-S2 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.4 versions prior to 20.4R3-S1 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.1 versions prior to 21.1R2-S2, 21.1R3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.2 versions prior to 21.2R1-S2, 21.2R2 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.3 versions prior to 21.3R1-S1, 21.3R2 on EX2300 Series, EX2300-MP Series, EX3400 Series.
CVE-2018-15504 2 Embedthis, Juniper 134 Appweb, Goahead, Ex2200 and 131 more 2023-12-10 5.0 MEDIUM 7.5 HIGH
An issue was discovered in Embedthis GoAhead before 4.0.1 and Appweb before 7.0.2. The server mishandles some HTTP request fields associated with time, which results in a NULL pointer dereference, as demonstrated by If-Modified-Since or If-Unmodified-Since with a month greater than 11.
CVE-2014-9708 3 Embedthis, Juniper, Oracle 134 Appweb, Ex2200, Ex2200-c and 131 more 2023-12-10 5.0 MEDIUM N/A
Embedthis Appweb before 4.6.6 and 5.x before 5.2.1 allows remote attackers to cause a denial of service (NULL pointer dereference) via a Range header with an empty value, as demonstrated by "Range: x=,".