Vulnerabilities (CVE)

Filtered by vendor Mitsubishielectric Subscribe
Filtered by product Gx Works3
Total 21 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-6942 1 Mitsubishielectric 10 Ezsocket, Fr Configurator2, Got1000 and 7 more 2024-02-08 N/A 7.5 HIGH
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, FR Configurator2 all versions, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 all versions, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally.
CVE-2023-6943 1 Mitsubishielectric 10 Ezsocket, Fr Configurator2, Got1000 and 7 more 2024-02-08 N/A 9.8 CRITICAL
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, FR Configurator2 all versions, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 all versions, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products.
CVE-2023-5247 1 Mitsubishielectric 4 Gx Works3, Melsoft Iq Appportal, Melsoft Navigator and 1 more 2023-12-10 N/A 7.8 HIGH
Malicious Code Execution Vulnerability due to External Control of File Name or Path in multiple Mitsubishi Electric FA Engineering Software Products allows a malicious attacker to execute a malicious code by having legitimate users open a specially crafted project file, which could result in information disclosure, tampering and deletion, or a denial-of-service (DoS) condition.
CVE-2023-4088 1 Mitsubishielectric 1 Gx Works3 2023-12-10 N/A 7.8 HIGH
Incorrect Default Permissions vulnerability due to incomplete fix to address CVE-2020-14496 in Mitsubishi Electric Corporation FA engineering software products allows a malicious local attacker to execute a malicious code, which could result in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition. However, if the mitigated version described in the advisory for CVE-2020-14496 is used and installed in the default installation folder, this vulnerability does not affect the products.
CVE-2022-29832 1 Mitsubishielectric 1 Gx Works3 2023-12-10 N/A 6.5 MEDIUM
Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could obtain information about the project file for MELSEC safety CPU modules or project file for MELSEC Q/FX/L series with security setting.
CVE-2022-29829 1 Mitsubishielectric 1 Gx Works3 2023-12-10 N/A 7.5 HIGH
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C and Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
CVE-2022-29830 1 Mitsubishielectric 1 Gx Works3 2023-12-10 N/A 9.1 CRITICAL
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.
CVE-2022-29833 1 Mitsubishielectric 1 Gx Works3 2023-12-10 N/A 6.5 MEDIUM
Insufficiently Protected Credentials vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could access to MELSEC safety CPU modules illgally.
CVE-2022-29827 1 Mitsubishielectric 1 Gx Works3 2023-12-10 N/A 7.5 HIGH
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally.
CVE-2022-29826 1 Mitsubishielectric 1 Gx Works3 2023-12-10 N/A 7.5 HIGH
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
CVE-2022-29825 1 Mitsubishielectric 1 Gx Works3 2023-12-10 N/A 7.5 HIGH
Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U and GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
CVE-2022-29831 1 Mitsubishielectric 1 Gx Works3 2023-12-10 N/A 7.5 HIGH
Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules.
CVE-2022-29828 1 Mitsubishielectric 1 Gx Works3 2023-12-10 N/A 7.5 HIGH
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute programs illegally.
CVE-2022-25164 1 Mitsubishielectric 2 Gx Works3, Mx Opc Ua Module Configurator-r 2023-12-10 N/A 7.5 HIGH
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.
CVE-2020-14521 1 Mitsubishielectric 60 C Controller Interface Module Utility, C Controller Module Setting And Monitoring Tool, Cc-link Ie Control Network Data Collector and 57 more 2023-12-10 7.5 HIGH 9.8 CRITICAL
Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition.
CVE-2020-14523 1 Mitsubishielectric 27 Cw Configurator, Fr Configurator2, Gx Works2 and 24 more 2023-12-10 7.5 HIGH 9.8 CRITICAL
Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code.
CVE-2020-14496 1 Mitsubishielectric 29 Cpu Module Logging Configuration Tool, Cw Configurator, Data Transfer and 26 more 2023-12-10 7.5 HIGH 9.8 CRITICAL
Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed.
CVE-2021-20587 1 Mitsubishielectric 41 C Controller Module Setting And Monitoring Tool, Cpu Module Logging Configuration Tool, Cw Configurator and 38 more 2023-12-10 7.5 HIGH 9.8 CRITICAL
Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
CVE-2021-20588 1 Mitsubishielectric 41 C Controller Module Setting And Monitoring Tool, Cpu Module Logging Configuration Tool, Cw Configurator and 38 more 2023-12-10 7.5 HIGH 9.8 CRITICAL
Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
CVE-2020-5602 1 Mitsubishielectric 20 Cpu Module Logging Configuration Tool, Cw Configurator, Em Configurator and 17 more 2023-12-10 5.0 MEDIUM 7.5 HIGH
Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to conduct XML External Entity (XXE) attacks via unspecified vectors.