Vulnerabilities (CVE)

Filtered by vendor Philips Subscribe
Total 101 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-26248 1 Philips 4 Mri 1.5t, Mri 1.5t Firmware, Mri 3t and 1 more 2023-12-10 2.1 LOW 5.5 MEDIUM
Philips MRI 1.5T and MRI 3T Version 5.x.x assigns an owner who is outside the intended control sphere to a resource.
CVE-2021-42744 1 Philips 4 Mri 1.5t, Mri 1.5t Firmware, Mri 3t and 1 more 2023-12-10 2.1 LOW 5.5 MEDIUM
Philips MRI 1.5T and MRI 3T Version 5.x.x exposes sensitive information to an actor not explicitly authorized to have access.
CVE-2021-43548 1 Philips 1 Patient Information Center Ix 2023-12-10 3.3 LOW 6.5 MEDIUM
Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
CVE-2021-26262 1 Philips 4 Mri 1.5t, Mri 1.5t Firmware, Mri 3t and 1 more 2023-12-10 5.0 MEDIUM 5.5 MEDIUM
Philips MRI 1.5T and MRI 3T Version 5.x.x does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
CVE-2021-43552 1 Philips 1 Patient Information Center Ix 2023-12-10 2.1 LOW 5.5 MEDIUM
The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03.
CVE-2021-23173 1 Philips 1 Engage 2023-12-10 4.0 MEDIUM 4.3 MEDIUM
The affected product is vulnerable to an improper access control, which may allow an authenticated user to gain unauthorized access to sensitive data.
CVE-2021-43550 1 Philips 3 Efficia Cm, Efficia Cm Firmware, Patient Information Center Ix 2023-12-10 3.3 LOW 6.5 MEDIUM
The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series Revisions A.01 to C.0x and 4.0.
CVE-2021-32993 1 Philips 4 Intellibridge Ec40, Intellibridge Ec40 Firmware, Intellibridge Ec80 and 1 more 2023-12-10 5.8 MEDIUM 8.8 HIGH
IntelliBridge EC 40 and 60 Hub (C.00.04 and prior) contains hard-coded credentials, such as a password or a cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data.
CVE-2021-39376 1 Philips 1 Tasy Electronic Medical Record 2023-12-10 6.5 MEDIUM 8.8 HIGH
Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the CorCad_F2/executaConsultaEspecifico IE_CORPO_ASSIST or CD_USUARIO_CONVENIO parameter.
CVE-2021-39375 1 Philips 1 Tasy Electronic Medical Record 2023-12-10 6.5 MEDIUM 8.8 HIGH
Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the WAdvancedFilter/getDimensionItemsByCode FilterValue parameter.
CVE-2020-16200 1 Philips 1 Clinical Collaboration Platform 2023-12-10 3.3 LOW 6.5 MEDIUM
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The software does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources.
CVE-2020-16198 1 Philips 1 Clinical Collaboration Platform 2023-12-10 5.8 MEDIUM 6.3 MEDIUM
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. When an attacker claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
CVE-2020-16247 1 Philips 1 Clinical Collaboration Platform 2023-12-10 3.6 LOW 7.1 HIGH
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.
CVE-2020-14506 1 Philips 1 Clinical Collaboration Platform 2023-12-10 4.3 MEDIUM 4.3 MEDIUM
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
CVE-2020-27298 1 Philips 5 Coronary Tools, Dynamic Coronary Roadmap, Interventional Workspot and 2 more 2023-12-10 3.3 LOW 6.5 MEDIUM
Philips Interventional Workspot (Release 1.3.2, 1.4.0, 1.4.1, 1.4.3, 1.4.5), Coronary Tools/Dynamic Coronary Roadmap/Stentboost Live (Release 1.0), ViewForum (Release 6.3V1L10). The software constructs all or part of an OS command using externally influenced input from an upstream component but does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when sent to a downstream component.
CVE-2018-7580 1 Philips 2 Hue, Hue Firmware 2023-12-10 5.0 MEDIUM 7.5 HIGH
Philips Hue is vulnerable to a Denial of Service attack. Sending a SYN flood on port tcp/80 will freeze Philips Hue's hub and it will stop responding. The "hub" will stop operating and be frozen until the flood stops. During the flood, the user won't be able to turn on/off the lights, and all of the hub's functionality will be unresponsive. The cloud service also won't work with the hub.
CVE-2020-14525 1 Philips 1 Clinical Collaboration Platform 2023-12-10 2.7 LOW 3.5 LOW
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users.
CVE-2020-12023 1 Philips 1 Intellibridge Enterprise 2023-12-10 2.7 LOW 4.5 MEDIUM
Philips IntelliBridge Enterprise (IBE), Versions B.12 and prior, IntelliBridge Enterprise system integration with SureSigns (VS4), EarlyVue (VS30) and IntelliVue Guardian (IGS). Unencrypted user credentials received in the IntelliBridge Enterprise (IBE) are logged within the transaction logs, which are secured behind the login based administrative web portal. The unencrypted user credentials sent from the affected products listed above, for the purpose of handshake or authentication with the Enterprise Systems, are logged as the payload in IntelliBridge Enterprise (IBE) within the transaction logs. An attacker with administrative privileges could exploit this vulnerability to read plain text credentials from log files.
CVE-2020-14477 1 Philips 16 Affiniti 50, Affiniti 50 Firmware, Affiniti 70 and 13 more 2023-12-10 3.6 LOW 4.4 MEDIUM
In Philips Ultrasound ClearVue Versions 3.2 and prior, Ultrasound CX Versions 5.0.2 and prior, Ultrasound EPIQ/Affiniti Versions VM5.0 and prior, Ultrasound Sparq Version 3.0.2 and prior and Ultrasound Xperius all versions, an attacker may use an alternate path or channel that does not require authentication of the alternate service login to view or modify information.
CVE-2020-11618 2 Philips, Thomsonstb 4 Dtr3502bfta Dvb-t2, Dtr3502bfta Dvb-t2 Firmware, Tht741fta and 1 more 2023-12-10 7.2 HIGH 7.8 HIGH
THOMSON THT741FTA 2.2.1 and Philips DTR3502BFTA DVB-T2 2.2.1 set-top boxes have their TELNET service hardcoded to start on boot, which allows an attacker on the local network to achieve root access via the TELNET protocol.