CVE-2023-27856 1 Rockwellautomation 1 Thinmanager 2023-12-10 N/A 7.5 HIGH
In affected versions, path traversal exists when processing a message of type 8 in Rockwell Automation's ThinManager ThinServer. An unauthenticated remote attacker can exploit this vulnerability to download arbitrary files on the disk drive where ThinServer.exe is installed.
CVE-2023-2444 1 Rockwellautomation 1 Factorytalk Vantagepoint 2023-12-10 N/A 8.8 HIGH
A cross site request forgery vulnerability exists in Rockwell Automation's FactoryTalk Vantagepoint. This vulnerability can be exploited in two ways. If an attacker sends a malicious link to a computer that is on the same domain as the FactoryTalk Vantagepoint server and a user clicks the link, the attacker could impersonate the legitimate user and send requests to the affected product.  Additionally, if an attacker sends an untrusted link to a computer that is not on the same domain as the server and a user opens the FactoryTalk Vantagepoint website, enters credentials for the FactoryTalk Vantagepoint server, and clicks on the malicious link a cross site request forgery attack would be successful as well.
CVE-2023-29460 1 Rockwellautomation 1 Arena Simulation 2023-12-10 N/A 9.8 CRITICAL
An arbitrary code execution vulnerability contained in Rockwell Automation's Arena Simulation software was reported that could potentially allow a malicious user to commit unauthorized arbitrary code to the software by using a memory buffer overflow potentially resulting in a complete loss of confidentiality, integrity, and availability.
CVE-2023-29027 1 Rockwellautomation 4 Armorstart St 281e, Armorstart St 281e Firmware, Armorstart St 284ee and 1 more 2023-12-10 N/A 5.9 MEDIUM
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user with admin privileges and network access to view user data and modify the web interface. Additionally, a malicious user could potentially cause interruptions to the availability of the web page.
CVE-2023-29022 1 Rockwellautomation 4 Armorstart St 281e, Armorstart St 281e Firmware, Armorstart St 284ee and 1 more 2023-12-10 N/A 5.9 MEDIUM
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user with admin privileges and network access to view user data and modify the web interface. Additionally, a malicious user could potentially cause interruptions to the availability of the web page.
CVE-2023-29026 1 Rockwellautomation 4 Armorstart St 281e, Armorstart St 281e Firmware, Armorstart St 284ee and 1 more 2023-12-10 N/A 5.9 MEDIUM
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user with admin privileges and network access to view user data and modify the web interface. Additionally, a malicious user could potentially cause interruptions to the availability of the web page.
CVE-2022-2825 4 Ge, Ptc, Rockwellautomation and 1 more 8 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 5 more 2023-12-10 N/A 9.8 CRITICAL
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-18411.
CVE-2022-3166 1 Rockwellautomation 4 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 1 more 2023-12-10 N/A 7.5 HIGH
Rockwell Automation was made aware that the webservers of the Micrologix 1100 and 1400 controllers contain a vulnerability that may lead to a denial-of-service condition. The security vulnerability could be exploited by an attacker with network access to the affected systems by sending TCP packets to webserver and closing it abruptly which would cause a denial-of-service condition for the web server application on the device
CVE-2023-0754 3 Ge, Ptc, Rockwellautomation 9 Digital Industrial Gateway Server, Kepware Server, Kepware Serverex and 6 more 2023-12-10 N/A 9.8 CRITICAL
The affected products are vulnerable to an integer overflow or wraparound, which could  allow an attacker to crash the server and remotely execute arbitrary code.
CVE-2022-3156 1 Rockwellautomation 1 Studio 5000 Logix Emulate 2023-12-10 N/A 7.8 HIGH
A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software.  Users are granted elevated permissions on certain product services when the software is installed. Due to this misconfiguration, a malicious user could potentially achieve remote code execution on the targeted software.
CVE-2023-0755 3 Ge, Ptc, Rockwellautomation 9 Digital Industrial Gateway Server, Kepware Server, Kepware Serverex and 6 more 2023-12-10 N/A 9.8 CRITICAL
The affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.
CVE-2022-3752 1 Rockwellautomation 10 Compact Guardlogix 5380, Compact Guardlogix 5380 Firmware, Compactlogix 5380 and 7 more 2023-12-10 N/A 7.5 HIGH
An unauthorized user could use a specially crafted sequence of Ethernet/IP messages, combined with heavy traffic loading to cause a denial-of-service condition in Rockwell Automation Logix controllers resulting in a major non-recoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online and continue normal operation.
CVE-2022-3157 1 Rockwellautomation 12 Compact Guardlogix 5370, Compact Guardlogix 5370 Firmware, Compact Guardlogix 5380 and 9 more 2023-12-10 N/A 7.5 HIGH
A vulnerability exists in the Rockwell Automation controllers that allows a malformed CIP request to cause a major non-recoverable fault (MNRF) and a denial-of-service condition (DOS).
CVE-2023-0027 1 Rockwellautomation 1 Modbus Tcp Server Add On Instructions 2023-12-10 N/A 4.3 MEDIUM
Rockwell Automation Modbus TCP Server AOI prior to 2.04.00 is vulnerable to an unauthorized user sending a malformed message that could cause the controller to respond with a copy of the most recent response to the last valid request. If exploited, an unauthorized user could read the connected device’s Modbus TCP Server AOI information.
CVE-2022-46670 1 Rockwellautomation 10 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 7 more 2023-12-10 N/A 6.1 MEDIUM
Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution.  The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website.
CVE-2022-2465 1 Rockwellautomation 1 Isagraf Workbench 2023-12-10 N/A 7.8 HIGH
Rockwell Automation ISaGRAF Workbench software versions 6.0 through 6.6.9 are affected by a Deserialization of Untrusted Data vulnerability. ISaGRAF Workbench does not limit the objects that can be deserialized. This vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user in ISaGRAF Workbench, may result in remote code execution. This vulnerability requires user interaction to be successfully exploited.
CVE-2022-2464 1 Rockwellautomation 1 Isagraf Workbench 2023-12-10 N/A 7.8 HIGH
Rockwell Automation ISaGRAF Workbench software versions 6.0 through 6.6.9 are affected by a Path Traversal vulnerability. Crafted malicious files can allow an attacker to traverse the file system when opened by ISaGRAF Workbench. If successfully exploited, an attacker could overwrite existing files and create additional files with the same permissions of the ISaGRAF Workbench software. User interaction is required for this exploit to be successful.
CVE-2022-38744 1 Rockwellautomation 1 Factorytalk Alarms And Events 2023-12-10 N/A 7.5 HIGH
An unauthenticated attacker with network access to a victim's Rockwell Automation FactoryTalk Alarm and Events service could open a connection, causing the service to fault and become unavailable. The affected port could be used as a server ping port and uses messages structured with XML.
CVE-2022-2463 1 Rockwellautomation 1 Isagraf Workbench 2023-12-10 N/A 7.8 HIGH
Rockwell Automation ISaGRAF Workbench software versions 6.0 through 6.6.9 are affected by a Path Traversal vulnerability. A crafted malicious .7z exchange file may allow an attacker to gain the privileges of the ISaGRAF Workbench software when opened. If the software is running at the SYSTEM level, then the attacker will gain admin level privileges. User interaction is required for this exploit to be successful.
CVE-2022-38742 1 Rockwellautomation 1 Thinmanager 2023-12-10 N/A 9.8 CRITICAL
Rockwell Automation ThinManager ThinServer versions 11.0.0 - 13.0.0 is vulnerable to a heap-based buffer overflow. An attacker could send a specifically crafted TFTP or HTTPS request, causing a heap-based buffer overflow that crashes the ThinServer process. If successfully exploited, this could expose the server to arbitrary remote code execution.