Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
Filtered by product Simatic Tdc Cp51m1
Total 6 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-25622 1 Siemens 23 Simatic Cfu Diq, Simatic Cfu Diq Firmware, Simatic Cfu Pa and 20 more 2023-12-10 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIMATIC CFU DIQ, SIMATIC CFU PA, SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200AL IM157-1 PN, SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L, SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L, SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L, SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L, SIMATIC ET200ecoPN, DI 16x24VDC, M12-L, SIMATIC ET200ecoPN, DI 8x24VDC, M12-L, SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L, SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 MF HF, SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC PN/MF Coupler, SIMATIC PN/PN Coupler, SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 CPU 414-3 PN/DP V7, SIMATIC S7-400 CPU 414F-3 PN/DP V7, SIMATIC S7-400 CPU 416-3 PN/DP V7, SIMATIC S7-400 CPU 416F-3 PN/DP V7, SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SINAMICS DCM, SINAMICS G110M, SINAMICS G115D, SINAMICS G120 (incl. SIPLUS variants), SINAMICS G130, SINAMICS G150, SINAMICS S110, SINAMICS S120 (incl. SIPLUS variants), SINAMICS S150, SINAMICS S210, SINAMICS V90, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS HCS4200 CIM4210, SIPLUS HCS4200 CIM4210C, SIPLUS HCS4300 CIM4310, SIPLUS NET PN/PN Coupler, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.
CVE-2019-19300 1 Siemens 65 Ktk Ate530s, Ktk Ate530s Firmware, Sidoor Atd430w and 62 more 2023-12-10 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), KTK ATE530S (All versions), SIDOOR ATD430W (All versions), SIDOOR ATE530S COATED (All versions), SIDOOR ATE531S (All versions), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions < V2.0), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.0), SIMATIC ET200AL IM157-1 PN (All versions), SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (All versions >= V5.1.1), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 MF HF (All versions), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC MICRO-DRIVE PDC (All versions), SIMATIC PN/MF Coupler (All versions), SIMATIC PN/PN Coupler (All versions >= V4.2), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.0), SIMATIC S7-1500 Software Controller (All versions < V2.0), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions), SIMATIC S7-300 CPU 315-2 PN/DP (All versions), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions), SIMATIC S7-300 CPU 317-2 PN/DP (All versions), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions), SIMATIC S7-300 CPU 319-3 PN/DP (All versions), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions), SIMATIC S7-400 H V6 CPU family and below (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions), SIMATIC TDC CP51M1 (All versions), SIMATIC TDC CPU555 (All versions), SIMATIC WinAC RTX 2010 (All versions), SIMATIC WinAC RTX F 2010 (All versions), SINAMICS S/G Control Unit w. PROFINET (All versions), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions), SIPLUS NET PN/PN Coupler (All versions >= V4.2), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions), SIPLUS S7-300 CPU 315-2 PN/DP (All versions), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions), SIPLUS S7-300 CPU 317-2 PN/DP (All versions), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions). The Interniche-based TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.
CVE-2019-18336 1 Siemens 23 Simatic S7-300 Cpu, Simatic S7-300 Cpu 312 Ifm, Simatic S7-300 Cpu 312 Ifm Firmware and 20 more 2023-12-10 7.8 HIGH 7.5 HIGH
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-10937 1 Siemens 2 Simatic Tdc Cp51m1, Simatic Tdc Cp51m1 Firmware 2023-12-10 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIMATIC TDC CP51M1 (All versions < V1.1.7). An attacker with network access to the device could cause a Denial-of-Service condition by sending a specially crafted UDP packet. The vulnerability affects the UDP communication of the device. The security vulnerability could be exploited without authentication. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2017-2681 1 Siemens 155 Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware, Ek-ertec 200 Pn Io and 152 more 2023-12-10 6.1 MEDIUM 6.5 MEDIUM
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices.
CVE-2017-2680 1 Siemens 183 S110 Pn, Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware and 180 more 2023-12-10 6.1 MEDIUM 6.5 MEDIUM
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.