Filtered by vendor Tenda
Subscribe
Total
741 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2023-39785 | 1 Tenda | 2 Ac8v4, Ac8v4 Firmware | 2023-12-10 | N/A | 7.5 HIGH |
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the set_qosMib_list function. | |||||
CVE-2023-40830 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-12-10 | N/A | 9.8 CRITICAL |
Tenda AC6 v15.03.05.19 is vulnerable to Buffer Overflow as the Index parameter does not verify the length. | |||||
CVE-2023-41554 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-12-10 | N/A | 9.8 CRITICAL |
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet. | |||||
CVE-2023-41552 | 1 Tenda | 4 Ac7, Ac7 Firmware, Ac9 and 1 more | 2023-12-10 | N/A | 9.8 CRITICAL |
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set. | |||||
CVE-2023-37721 | 1 Tenda | 10 4g300, 4g300 Firmware, F1202 and 7 more | 2023-12-10 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeMacFilter. | |||||
CVE-2023-38936 | 1 Tenda | 18 Ac10, Ac10 Firmware, Ac1206 and 15 more | 2023-12-10 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. | |||||
CVE-2023-37719 | 1 Tenda | 8 F1202, F1202 Firmware, Fh1202 and 5 more | 2023-12-10 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromP2pListFilter. | |||||
CVE-2023-37722 | 1 Tenda | 6 4g300, 4g300 Firmware, F1202 and 3 more | 2023-12-10 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeUrlFilter. | |||||
CVE-2023-40802 | 1 Tenda | 2 Ac23, Ac23 Firmware | 2023-12-10 | N/A | 6.5 MEDIUM |
The get_parentControl_list_Info function does not verify the parameters entered by the user, causing a post-authentication heap overflow vulnerability in Tenda AC23 v16.03.07.45_cn | |||||
CVE-2023-41555 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2023-12-10 | N/A | 9.8 CRITICAL |
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasicSet. | |||||
CVE-2023-40846 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-12-10 | N/A | 9.8 CRITICAL |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function sub_90998. | |||||
CVE-2023-40915 | 1 Tenda | 2 Ax3, Ax3 Firmware | 2023-12-10 | N/A | 7.5 HIGH |
Tenda AX3 v16.03.12.11 has a stack buffer overflow vulnerability detected at function form_fast_setting_wifi_set. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ssid parameter. | |||||
CVE-2023-39829 | 1 Tenda | 2 A18, A18 Firmware | 2023-12-10 | N/A | 7.5 HIGH |
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the wpapsk_crypto2_4g parameter in the fromSetWirelessRepeat function. | |||||
CVE-2023-40894 | 1 Tenda | 2 Ac8v4, Ac8v4 Firmware | 2023-12-10 | N/A | 9.8 CRITICAL |
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetStaticRouteCfg. | |||||
CVE-2023-40895 | 1 Tenda | 2 Ac8v4, Ac8v4 Firmware | 2023-12-10 | N/A | 9.8 CRITICAL |
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg. | |||||
CVE-2023-37718 | 1 Tenda | 6 4g300, 4g300 Firmware, F1202 and 3 more | 2023-12-10 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeClientFilter. | |||||
CVE-2023-46370 | 1 Tenda | 2 W18e, W18e Firmware | 2023-12-10 | N/A | 9.8 CRITICAL |
Tenda W18E V16.01.0.8(1576) has a command injection vulnerability via the hostName parameter in the formSetNetCheckTools function. | |||||
CVE-2023-38940 | 1 Tenda | 6 F1203, F1203 Firmware, Fh1203 and 3 more | 2023-12-10 | N/A | 9.8 CRITICAL |
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function. | |||||
CVE-2023-40899 | 1 Tenda | 2 Ac8v4, Ac8v4 Firmware | 2023-12-10 | N/A | 9.8 CRITICAL |
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg. | |||||
CVE-2023-37715 | 1 Tenda | 4 F1202, F1202 Firmware, Fh1202 and 1 more | 2023-12-10 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm. |