Vulnerabilities (CVE)

Filtered by vendor Codesys Subscribe
Filtered by product Control Rte Sl
Total 29 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-4224 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2024-02-01 N/A 8.8 HIGH
In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the device.
CVE-2023-37548 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2023-12-10 N/A 6.5 MEDIUM
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550
CVE-2023-37552 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2023-12-10 N/A 6.5 MEDIUM
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
CVE-2023-37545 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2023-12-10 N/A 6.5 MEDIUM
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550
CVE-2022-4046 1 Codesys 14 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 11 more 2023-12-10 N/A 8.8 HIGH
In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device.
CVE-2023-37551 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2023-12-10 N/A 6.5 MEDIUM
In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller.
CVE-2023-37546 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2023-12-10 N/A 6.5 MEDIUM
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550
CVE-2023-37559 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2023-12-10 N/A 6.5 MEDIUM
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558
CVE-2023-37556 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2023-12-10 N/A 6.5 MEDIUM
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37555.
CVE-2023-37557 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2023-12-10 N/A 6.5 MEDIUM
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition.
CVE-2023-37550 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2023-12-10 N/A 6.5 MEDIUM
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.
CVE-2023-37553 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2023-12-10 N/A 6.5 MEDIUM
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
CVE-2023-37549 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2023-12-10 N/A 6.5 MEDIUM
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550
CVE-2023-37555 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2023-12-10 N/A 6.5 MEDIUM
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37556.
CVE-2023-37547 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2023-12-10 N/A 6.5 MEDIUM
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550
CVE-2023-37558 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2023-12-10 N/A 6.5 MEDIUM
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559
CVE-2023-37554 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2023-12-10 N/A 6.5 MEDIUM
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37555 and CVE-2023-37556.
CVE-2022-30792 1 Codesys 19 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 Sl and 16 more 2023-12-10 5.0 MEDIUM 7.5 HIGH
In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected.
CVE-2022-30791 1 Codesys 19 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 Sl and 16 more 2023-12-10 5.0 MEDIUM 7.5 HIGH
In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected.
CVE-2022-22516 2 Codesys, Microsoft 5 Control Rte Sl, Control Rte Sl \(for Beckhoff Cx\), Control Win Sl and 2 more 2023-12-10 7.2 HIGH 7.8 HIGH
The SysDrv3S driver in the CODESYS Control runtime system on Microsoft Windows allows any system user to read and write within restricted memory space.