Vulnerabilities (CVE)

Filtered by vendor Gehealthcare Subscribe
Total 34 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2020-25179 1 Gehealthcare 224 1.5t Brivo Mr355, 1.5t Brivo Mr355 Firmware, 3.0t Signa Hd 16 and 221 more 2023-12-10 7.5 HIGH 9.8 CRITICAL
GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.
CVE-2020-25175 1 Gehealthcare 224 1.5t Brivo Mr355, 1.5t Brivo Mr355 Firmware, 3.0t Signa Hd 16 and 221 more 2023-12-10 5.0 MEDIUM 9.8 CRITICAL
GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.
CVE-2020-6963 1 Gehealthcare 12 Apexpro Telemetry Server, Apexpro Telemetry Server Firmware, Carescape Central Station Mai700 and 9 more 2023-12-10 10.0 HIGH 10.0 CRITICAL
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execute arbitrary code.
CVE-2020-6964 1 Gehealthcare 12 Apexpro Telemetry Server, Apexpro Telemetry Server Firmware, Carescape Central Station Mai700 and 9 more 2023-12-10 5.0 MEDIUM 8.6 HIGH
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network.
CVE-2020-6965 1 Gehealthcare 18 Apexpro Telemetry Server, Apexpro Telemetry Server Firmware, Carescape B450 Monitor and 15 more 2023-12-10 6.5 MEDIUM 9.9 CRITICAL
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package.
CVE-2020-6962 1 Gehealthcare 18 Apexpro Telemetry Server, Apexpro Telemetry Server Firmware, Carescape B450 Monitor and 15 more 2023-12-10 10.0 HIGH 10.0 CRITICAL
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution.
CVE-2020-6966 1 Gehealthcare 12 Apexpro Telemetry Server, Apexpro Telemetry Server Firmware, Carescape Central Station Mai700 and 9 more 2023-12-10 10.0 HIGH 10.0 CRITICAL
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilize a weak encryption scheme for remote desktop control, which may allow an attacker to obtain remote code execution of devices on the network.
CVE-2020-6961 1 Gehealthcare 12 Apexpro Telemetry Server, Apexpro Telemetry Server Firmware, Carescape Central Station Mai700 and 9 more 2023-12-10 7.5 HIGH 10.0 CRITICAL
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X, a vulnerability exists in the affected products that could allow an attacker to obtain access to the SSH private key in configuration files.
CVE-2014-7232 1 Gehealthcare 2 Discovery Xr656, Discovery Xr656 G2 2023-12-10 10.0 HIGH N/A
GE Healthcare Discovery XR656 and XR656 G2 has a password of (1) 2getin for the insite user, (2) 4$xray for the xruser user, and (3) #superxr for the root user, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value.
CVE-2013-7404 1 Gehealthcare 1 Discovery Nm 750b 2023-12-10 10.0 HIGH N/A
GE Healthcare Discovery NM 750b has a password of 2getin for the insite account for (1) Telnet and (2) FTP, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
CVE-2007-6757 1 Gehealthcare 1 Centricity Dms Firmware 2023-12-10 10.0 HIGH N/A
GE Healthcare Centricity DMS 4.2, 4.1, and 4.0 has a password of Muse!Admin for the Museadmin user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
CVE-2010-5307 1 Gehealthcare 1 Optima Mr360 Firmware 2023-12-10 10.0 HIGH N/A
The HIPAA configuration interface in GE Healthcare Optima MR360 has a password of (1) operator for the root account, (2) adw2.0 for the admin account, and (3) adw2.0 for the sdc account, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value.
CVE-2012-6693 1 Gehealthcare 1 Centricity Pacs Server 2023-12-10 10.0 HIGH N/A
GE Healthcare Centricity PACS 4.0 Server has a default password of (1) nasro for the nasro (ReadOnly) user and (2) nasrw for the nasrw (Read/Write) user, which has unspecified impact and attack vectors.
CVE-2003-1603 1 Gehealthcare 1 Discovery Vh 2023-12-10 10.0 HIGH N/A
GE Healthcare Discovery VH has a default password of (1) interfile for the ftpclient user of the Interfile server or (2) "2" for the LOCAL user of the FTP server for the Codonics printer, which has unspecified impact and attack vectors.
CVE-2011-5323 1 Gehealthcare 1 Centricity Pacs-iw 2023-12-10 10.0 HIGH N/A
GE Healthcare Centricity PACS-IW 3.7.3.7, 3.7.3.8, and possibly other versions has a password of A11enda1e for the sa SQL server user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
CVE-2012-6660 1 Gehealthcare 1 Precision Mpi 2023-12-10 10.0 HIGH N/A
GE Healthcare Precision MPi has a password of (1) orion for the serviceapp user, (2) orion for the clinical operator user, and (3) PlatinumOne for the administrator user, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value.
CVE-2002-2446 1 Gehealthcare 3 Millennium Mg Firmware, Millennium Myosight Firmware, Millennium Nc Firmware 2023-12-10 10.0 HIGH N/A
GE Healthcare Millennium MG, NC, and MyoSIGHT has a password of insite.genieacq for the insite account that cannot be changed without disabling product functionality for remote InSite support, which has unspecified impact and attack vectors.
CVE-2013-7405 1 Gehealthcare 1 Centricity Dms 2023-12-10 10.0 HIGH N/A
The Ad Hoc Reporting feature in GE Healthcare Centricity DMS 4.2 has a password of Never!Mind for the Administrator user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
CVE-2011-5324 1 Gehealthcare 1 Centricity Pacs-iw 2023-12-10 10.0 HIGH N/A
The TeraRecon server, as used in GE Healthcare Centricity PACS-IW 3.7.3.7, 3.7.3.8, and possibly other versions, has a password of (1) shared for the shared user and (2) scan for the scan user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
CVE-2001-1594 1 Gehealthcare 1 Entegra P\&r 2023-12-10 10.0 HIGH N/A
GE Healthcare eNTEGRA P&R has a password of (1) entegra for the entegra user, (2) passme for the super user of the Polestar/Polestar-i Starlink 4 upgrade, (3) 0 for the entegra user of the Codonics printer FTP service, (4) eNTEGRA for the eNTEGRA P&R user account, (5) insite for the WinVNC Login, and possibly other accounts, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.