Vulnerabilities (CVE)

Filtered by vendor Juniper Subscribe
Filtered by product Ex4100
Total 5 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-21620 1 Juniper 105 Ex2200, Ex2200-c, Ex2200-vc and 102 more 2024-02-01 N/A 6.1 MEDIUM
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in J-Web of Juniper Networks Junos OS on SRX Series and EX Series allows an attacker to construct a URL that when visited by another user enables the attacker to execute commands with the target's permissions, including an administrator. A specific invocation of the emit_debug_note method in webauth_operation.php will echo back the data it receives. This issue affects Juniper Networks Junos OS on SRX Series and EX Series: * All versions earlier than 20.4R3-S10; * 21.2 versions earlier than 21.2R3-S8; * 21.4 versions earlier than 21.4R3-S6; * 22.1 versions earlier than 22.1R3-S5; * 22.2 versions earlier than 22.2R3-S3; * 22.3 versions earlier than 22.3R3-S2; * 22.4 versions earlier than 22.4R3-S1; * 23.2 versions earlier than 23.2R2; * 23.4 versions earlier than 23.4R2.
CVE-2024-21619 1 Juniper 105 Ex2200, Ex2200-c, Ex2200-vc and 102 more 2024-01-31 N/A 7.5 HIGH
A Missing Authentication for Critical Function vulnerability combined with a Generation of Error Message Containing Sensitive Information vulnerability in J-Web of Juniper Networks Junos OS on SRX Series and EX Series allows an unauthenticated, network-based attacker to access sensitive system information. When a user logs in, a temporary file which contains the configuration of the device (as visible to that user) is created in the /cache folder. An unauthenticated attacker can then attempt to access such a file by sending a specific request to the device trying to guess the name of such a file. Successful exploitation will reveal configuration information. This issue affects Juniper Networks Junos OS on SRX Series and EX Series: * All versions earlier than 20.4R3-S9; * 21.2 versions earlier than 21.2R3-S7; * 21.3 versions earlier than 21.3R3-S5; * 21.4 versions earlier than 21.4R3-S6; * 22.1 versions earlier than 22.1R3-S5; * 22.2 versions earlier than 22.2R3-S3; * 22.3 versions earlier than 22.3R3-S2; * 22.4 versions earlier than 22.4R3; * 23.2 versions earlier than 23.2R1-S2, 23.2R2.
CVE-2024-21595 1 Juniper 16 Ex4100, Ex4400, Ex4600 and 13 more 2024-01-18 N/A 7.5 HIGH
An Improper Validation of Syntactic Correctness of Input vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows a network-based, unauthenticated attacker to cause a Denial of Service (DoS). If an attacker sends high rate of specific ICMP traffic to a device with VXLAN configured, this causes a deadlock of the PFE and results in the device becoming unresponsive. A manual restart will be required to recover the device. This issue only affects EX4100, EX4400, EX4600, QFX5000 Series devices. This issue affects: Juniper Networks Junos OS * 21.4R3 versions earlier than 21.4R3-S4; * 22.1R3 versions earlier than 22.1R3-S3; * 22.2R2 versions earlier than 22.2R3-S1; * 22.3 versions earlier than 22.3R2-S2, 22.3R3; * 22.4 versions earlier than 22.4R2; * 23.1 versions earlier than 23.1R2.
CVE-2023-44191 1 Juniper 25 Ex2300, Ex2300-c, Ex2300 Multigigabit and 22 more 2023-12-10 N/A 7.5 HIGH
An Allocation of Resources Without Limits or Throttling vulnerability in Juniper Networks Junos OS allows an unauthenticated, network-based attacker to cause Denial of Service (DoS). On all Junos OS QFX5000 Series and EX4000 Series platforms, when a high number of VLANs are configured, a specific DHCP packet will cause PFE hogging which will lead to dropping of socket connections. This issue affects: Juniper Networks Junos OS on QFX5000 Series and EX4000 Series * 21.1 versions prior to 21.1R3-S5; * 21.2 versions prior to 21.2R3-S5; * 21.3 versions prior to 21.3R3-S5; * 21.4 versions prior to 21.4R3-S4; * 22.1 versions prior to 22.1R3-S3; * 22.2 versions prior to 22.2R3-S1; * 22.3 versions prior to 22.3R2-S2, 22.3R3; * 22.4 versions prior to 22.4R2. This issue does not affect Juniper Networks Junos OS versions prior to 21.1R1
CVE-2023-44203 1 Juniper 26 Ex2300, Ex2300-24mp, Ex2300-24p and 23 more 2023-12-10 N/A 6.5 MEDIUM
An Improper Check or Handling of Exceptional Conditions vulnerability in the Packet Forwarding Engine (pfe) of Juniper Networks Junos OS on QFX5000 Series, EX2300, EX3400, EX4100, EX4400 and EX4600 allows a adjacent attacker to send specific traffic, which leads to packet flooding, resulting in a Denial of Service (DoS). When a specific IGMP packet is received in an isolated VLAN, it is duplicated to all other ports under the primary VLAN, which causes a flood. This issue affects QFX5000 series, EX2300, EX3400, EX4100, EX4400 and EX4600 platforms only. This issue affects Juniper Junos OS on on QFX5000 Series, EX2300, EX3400, EX4100, EX4400 and EX4600: * All versions prior to 20.4R3-S5; * 21.1 versions prior to 21.1R3-S4; * 21.2 versions prior to 21.2R3-S3; * 21.3 versions prior to 21.3R3-S5; * 21.4 versions prior to 21.4R3-S2; * 22.1 versions prior to 22.1R3; * 22.2 versions prior to 22.2R3; * 22.3 versions prior to 22.3R2.