Vulnerabilities (CVE)

Filtered by CWE-788
Total 17 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-0229 2024-04-30 N/A 7.8 HIGH
An out-of-bounds memory access flaw was found in the X.Org server. This issue can be triggered when a device frozen by a sync grab is reattached to a different master device. This issue may lead to an application crash, local privilege escalation (if the server runs with extended privileges), or remote code execution in SSH X11 forwarding environments.
CVE-2024-21618 2024-04-15 N/A 6.5 MEDIUM
An Access of Memory Location After End of Buffer vulnerability in the Layer-2 Control Protocols Daemon (l2cpd) of Juniper Networks Junos OS and Junos OS Evolved allows an adjacent, unauthenticated attacker to cause Denial of Service (DoS). On all Junos OS and Junos OS Evolved platforms, when LLDP is enabled on a specific interface, and a malformed LLDP packet is received, l2cpd crashes and restarts. The impact of the l2cpd crash is reinitialization of STP protocols (RSTP, MSTP or VSTP), and MVRP and ERP. Also, if any services depend on LLDP state (like PoE or VoIP device recognition), then these will also be affected. This issue affects: Junos OS: * from 21.4 before 21.4R3-S4,  * from 22.1 before 22.1R3-S4,  * from 22.2 before 22.2R3-S2,  * from 22.3 before 22.3R2-S2, 22.3R3-S1,  * from 22.4 before 22.4R3,  * from 23.2 before 23.2R2. Junos OS Evolved: * from 21.4-EVO before 21.4R3-S5-EVO,  * from 22.1-EVO before 22.1R3-S4-EVO,  * from 22.2-EVO before 22.2R3-S2-EVO,  * from 22.3-EVO before 22.3R2-S2-EVO, 22.3R3-S1-EVO,  * from 22.4-EVO before 22.4R3-EVO,  * from 23.2-EVO before 23.2R2-EVO. This issue does not affect: * Junos OS versions prior to 21.4R1; * Junos OS Evolved versions prior to 21.4R1-EVO.
CVE-2024-0074 2024-03-28 N/A 7.1 HIGH
NVIDIA GPU Display Driver for Linux contains a vulnerability where an attacker may access a memory location after the end of the buffer. A successful exploit of this vulnerability may lead to denial of service and data tampering.
CVE-2024-0173 2024-03-13 N/A 3.8 LOW
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory.
CVE-2024-0154 2024-03-13 N/A 3.8 LOW
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory.
CVE-2023-20169 1 Cisco 35 Nexus 3048, Nexus 31108pc-v, Nexus 31108tc-v and 32 more 2024-01-25 N/A 7.4 HIGH
A vulnerability in the Intermediate System-to-Intermediate System (IS-IS) protocol of Cisco NX-OS Software for the Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches in standalone NX-OS mode could allow an unauthenticated, adjacent attacker to cause the IS-IS process to unexpectedly restart, which could cause an affected device to reload. This vulnerability is due to insufficient input validation when parsing an ingress IS-IS packet. An attacker could exploit this vulnerability by sending a crafted IS-IS packet to an affected device. A successful exploit could allow the attacker to cause a denial of service (DoS) condition due to the unexpected restart of the IS-IS process, which could cause the affected device to reload. Note: The IS-IS protocol is a routing protocol. To exploit this vulnerability, an attacker must be Layer 2 adjacent to the affected device.
CVE-2023-0103 1 Ls-electric 2 Xbc-dn32u, Xbc-dn32u Firmware 2023-12-10 N/A 7.5 HIGH
If an attacker were to access memory locations of LS ELECTRIC XBC-DN32U with operating system version 01.80 that are outside of the communication buffer, the device stops operating. This could allow an attacker to cause a denial-of-service condition.
CVE-2021-40727 3 Adobe, Apple, Microsoft 3 Indesign, Macos, Windows 2023-12-10 9.3 HIGH 7.8 HIGH
Access of Memory Location After End of Buffer (CWE-788
CVE-2021-42732 3 Adobe, Apple, Microsoft 3 Indesign, Macos, Windows 2023-12-10 6.8 MEDIUM 7.8 HIGH
Access of Memory Location After End of Buffer (CWE-788)
CVE-2021-40767 3 Adobe, Apple, Microsoft 3 Character Animator, Macos, Windows 2023-12-10 4.3 MEDIUM 5.5 MEDIUM
Adobe Character Animator version 4.4 (and earlier) is affected by an Access of Memory Location After End of Buffer vulnerability when parsing a specially crafted file. An unauthenticated attacker could leverage this vulnerability to achieve an application denial-of-service in the context of the current user. Exploitation of this issue requires user interaction in that a victim must open a malicious file.
CVE-2021-40741 3 Adobe, Apple, Microsoft 3 Audition, Macos, Windows 2023-12-10 4.3 MEDIUM 5.5 MEDIUM
Adobe Audition version 14.4 (and earlier) is affected by an Access of Memory Location After End of Buffer vulnerability when parsing a specially crafted file. An unauthenticated attacker could leverage this vulnerability to achieve an application denial-of-service in the context of the current user. Exploitation of this issue requires user interaction in that a victim must open a malicious file.
CVE-2021-42735 3 Adobe, Apple, Microsoft 3 Photoshop, Macos, Windows 2023-12-10 6.8 MEDIUM 7.8 HIGH
Adobe Photoshop version 22.5.1 (and earlier versions ) is affected by an Access of Memory Location After End of Buffer vulnerability, potentially resulting in arbitrary code execution in the context of the current user. User interaction is required to exploit this vulnerability.
CVE-2021-27384 1 Siemens 35 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 32 more 2023-12-10 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
CVE-2021-36052 2 Adobe, Debian 2 Xmp Toolkit Software Development Kit, Debian Linux 2023-12-10 6.8 MEDIUM 7.8 HIGH
XMP Toolkit version 2020.1 (and earlier) is affected by a memory corruption vulnerability, potentially resulting in arbitrary code execution in the context of the current user. User interaction is required to exploit this vulnerability.
CVE-2021-25660 1 Siemens 19 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 16 more 2023-12-10 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.
CVE-2021-32629 1 Bytecodealliance 1 Cranelift-codegen 2023-12-10 4.6 MEDIUM 8.8 HIGH
Cranelift is an open-source code generator maintained by Bytecode Alliance. It translates a target-independent intermediate representation into executable machine code. There is a bug in 0.73 of the Cranelift x64 backend that can create a scenario that could result in a potential sandbox escape in a Wasm program. This bug was introduced in the new backend on 2020-09-08 and first included in a release on 2020-09-30, but the new backend was not the default prior to 0.73. The recently-released version 0.73 with default settings, and prior versions with an explicit build flag to select the new backend, are vulnerable. The bug in question performs a sign-extend instead of a zero-extend on a value loaded from the stack, under a specific set of circumstances. If those circumstances occur, the bug could allow access to memory addresses upto 2GiB before the start of the Wasm program heap. If the heap bound is larger than 2GiB, then it would be possible to read memory from a computable range dependent on the size of the heaps bound. The impact of this bug is highly dependent on heap implementation, specifically: * if the heap has bounds checks, and * does not rely exclusively on guard pages, and * the heap bound is 2GiB or smaller * then this bug cannot be used to reach memory from another Wasm program heap. The impact of the vulnerability is mitigated if there is no memory mapped in the range accessible using this bug, for example, if there is a 2 GiB guard region before the Wasm program heap. The bug in question performs a sign-extend instead of a zero-extend on a value loaded from the stack, when the register allocator reloads a spilled integer value narrower than 64 bits. This interacts poorly with another optimization: the instruction selector elides a 32-to-64-bit zero-extend operator when we know that an instruction producing a 32-bit value actually zeros the upper 32 bits of its destination register. Hence, we rely on these zeroed bits, but the type of the value is still i32, and the spill/reload reconstitutes those bits as the sign extension of the i32’s MSB. The issue would thus occur when: * An i32 value in a Wasm program is greater than or equal to 0x8000_0000; * The value is spilled and reloaded by the register allocator due to high register pressure in the program between the value’s definition and its use; * The value is produced by an instruction that we know to be “special” in that it zeroes the upper 32 bits of its destination: add, sub, mul, and, or; * The value is then zero-extended to 64 bits in the Wasm program; * The resulting 64-bit value is used. Under these circumstances there is a potential sandbox escape when the i32 value is a pointer. The usual code emitted for heap accesses zero-extends the Wasm heap address, adds it to a 64-bit heap base, and accesses the resulting address. If the zero-extend becomes a sign-extend, the program could reach backward and access memory up to 2GiB before the start of its heap. In addition to assessing the nature of the code generation bug in Cranelift, we have also determined that under specific circumstances, both Lucet and Wasmtime using this version of Cranelift may be exploitable. See referenced GitHub Advisory for more details.
CVE-2021-25661 1 Siemens 19 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 16 more 2023-12-10 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition.